Managing the Z-Edge 64
Z-Edge 64 Configuration Guide
19
You can configure the Z-Edge 64 using any of the following methods:
•
Simple Network Management Protocol (SNMP)
•
Command Line Interface (CLI)
•
Zhone Management System (ZMS)
SNMP
The Z-Edge 64 supports SNMP version 1 and version 2 for system
management. Network object variables are MIB-II compliant.
SNMP can be accessed over IP interfaces or the Ethernet interface. The
SNMP agent on the Z-Edge 64 uses port 161 of user datagram protocol (UDP)
for management traffic and UDP port 162 for error events and SNMP traps.
The MIBs for the Z-Edge 64 control the following:
•
Data port configuration, status, and diagnostics
•
General system management, field upgrades, and alarms
•
Traps
CLI
The CLI is functionally similar to SNMP. The CLI commands are equivalent
to SNMP get and set commands and allow you to configure the unit. The
interface is accessible both using telnet and through a local serial port. You
can configure the same elements with the CLI as you can with SNMP.
ZMS
ZMS allows Z-Edge 64 users to navigate, monitor, and manage their Zhone
networks with a graphical user interface.