Deployment scenarios
zNID 24xx Series Configuration Guide
173
Figure 133: Selecting port members and their tagging
Normally the uplink
(Fiber WAN (eth0)
will be Tagged as in this
example. Select
T
from the
Fiber WAN (eth0)
dropdown.
In this example we are only selected one untagged downstream
interface. Select
U
from the
GE2 - GigE (eth2)
dropdown.
For Dual Managed connections that map to the VEIP select “O” for
the uplink port member.
b
Click
Save/Apply
c
From the
VLAN | Settings
page click
Edit Port Defaults
d
In the
PVID
text box for
GE2 - GigE eth2
, enter 205 (the same as the
ID for the VLAN)
Figure 134: Setting the PVID for the interface