iron.
2. The welding temperature can be regulated from 150
0
C to 450
0
C in steps by
means of two regulating switches ( +/ -). The temperature will increase ( +
△ ▽
△
switch) or decrease ( - switch) by 1
▽
0
C every time you press the switch momently.
If you press the switch without move, regulating will go on by10
0
C every grade till
the demanded temperature is displayed.
3
When the welding temperature is regulated to a wanted number, the factual
working temperature will approach the set temperature gradually.
Instructions:
. When the weld machine is turned off, the regulated temperature will be kept
automatically. And when you turn on the machine next time, this set
temperature will be displayed automatically.
. Once any malfunction happens for example the temperature sensor is
damaged, or the connecting lead between the electric iron and the weld
machine is disconnected, the display will show malfunction. Further, the
piezoelectricity sensor inside will give out sound of alarm. In that situation,
shut down the machine immediately, switch off the power supply and look up
possible cause resulting in malfunction.
Operation:
To make welding work perfect, you have to use the proper welding rod and
operate the weld machine accurately. Electric welding rod with colophony is
advised to use. Any welding preparation with halogen is forbidden. The welding
preparation on the rod can clear away the impurities and oxides on the welding
point that will do harm to welding and prevent new oxides from being created in
the course of welding. In practice, alloy solder L-SN60PbCu2
(
German Industry
Standard 8516
)
with 60% tin
(
60/40 solder
)
is mostly used. This solder has
many welding rod standards and 1mm welding rod is advised to use in electric
•only the operation safety of the weld machine is guaranteed, can we use the weld
machine. In the following circumstances, the operation safety may not available:
If there are damages which can be seen with our eyes, (for example, insulation has
‐
problems, the crust crazes );
the weld machine can not operate
‐
the weld machine is usually left under poor circumstances
‐
with inappropriate transportation
‐
the damaged weld machine is not allowed to be used again, and the power supply
‐
must be cut off, in case that some one who don’t know that will use it. If it needs
maintenance and repair, only the professionals with strict training can open the
weld machine to maintain and repair it. Self-disassembly may result in the danger
of electric shake, and in the risk of losing the right of the counterclaim based on
the quality guarantee.
•Only the voltage and frequency marked on the data plate can be used by the weld
machine.
•the weld machine can only be installed in the dry workshops to operate.
•the weld machine in operation must be looked after by workers.
•the weld machine can not operate or be put aside within the reach of the children.
•the weld machine can not be used under the wet circumstances or near the easily
flaming or the plosive materials or air.
•during the welding , it will produce welding evaporation, so welding can only be
allowed in the draught workshops.
•welding can only be carried out on the components with no electricity.
•You have to obey the corresponding regulation of safety protection, if the weld is
used in the industry.
•if the weld machine is moved from the cold room to the warm room, the
temperature will be changed, which will cause the congealed water which will
affect or damage the components of the machine, please wait to weld until the
temperature of the weld machine is the same with that in the room.
3
6