Shanghai Zhuoyi Electronic Co.,Ltd.
Add: 1# Building, No.118 Hangtou Rd., Pudong, Shanghai, China
Tel: 0086 21 33893666 33750266 Fax: 0086 21 33893668
Http://www.zhuo-yi.com Email: info@zhuo-yi.com
Timer Switch User Manual ZYT09
·Be sure to read the manual carefully before using.
·Please safekeeping the manual.
●
Function and Application
This product designed with high-performance microcomputer chip,
can automatically switch on and switch off various kinds of electric
equipments according to the fixed time with 40 groups and automatic
calibration function. It is widely used in programmable control of
electric cooker, booster, lamp, water heater, sprayer, bottler, preheater,
agriculture facilities, and broadcasting equipment and etc.
●
Technical Specifications
Voltage Range
:
220V 50Hz Voltage scope
:
85%
~
110%
Switch Capacitance: 20A Consumed power
<
3W
Programs: 40 sets Timing Control Range
:
1min
~
168h
Timing error <±0.5s/day Battery: Rechargeable
Temperature
:
-10
℃
~
+50
℃
Relative Humidity
:
<95%
Dimension
:
50×100×74mm Weight
:
185g
●
Function Key Description
6 keys: “Function key", “Select key”
、
“Addend key” “Subtractive key”
,
“Manual key”
,
“Reset
key”
,
and other functions shown as follow
:
1.Function key
:
function selection
Click it into the setting. Push continuously and check or set the clock key, program
key, error key and so on. Press it for 3 seconds and enter the state of clock display.
2.Select key
:
function parameters
。
In the function setting mode
,
clicking it you can select various parameters of a function
module or a few different parameters. And the selected parameter is blinking.
3.Addend key
:
parameter adjust
Select the specific parameter in positive direction.
4.Subtractive key
:
parameter adjust
Select the specific parameter in opposite direction.
5.Manual key
:
when the clock running, press the manually key to achieve the output state
transitions. Press it and the cycle order can be selected
:
“auto-on-auto-off”. In the
program state, press the "manual" button to cancel the current procedures for setting
parameters for :"-:-". Press it again and get the recovery the setting parameter last time.
6.Reset key
:
System reset, clear all the settings, the time to 00:00:00.
7.Other function
:
For 30 seconds without any operation, it will back to the clock display. Without external
power supply, meanwhile the clock running, press the "addend" button and "subtractive"
button for 2 seconds, it can close the liquid crystal display into the power-saving mode.
As the clock is running, for 5 minutes without any operation, it also comes into the
power-saving mode. When it is in the power-saving mode, press any key to wake it up.
●
Clock Calibration
1. Function options: press function key and select the clock function menu, "Clock"
2. Parameters: Press select key to select the time parameter (hours, minutes, seconds