res. make sure condens water formed on the flue wall can never enter the stove.
never install two or more stoves on one chimney.
B.2 vEntILAtIon And mEchAnIcAL vEntILAtIon
ensure to allow sufficient fresh air to enter the room. per hour an additional 50 m
3
air is needed above the normal ventilation requirement for the room.
Ventilation openings to be made close to the floor. choose position carefully. Ven-
tilation openings must not be blocked (not on inside nor on outside).
have a fresh air inlet to the room with a section of at least a quarter of the section
of the exhaust �ue, with a minimum of 100 cm
2
.
if stove is positioned in rooms equipped with mechanical ventilation the following
guidelines apply:
Capacity of mechanical ventilation
[m
3
/h]
Additional required ventilation
section [cm
2
]
<50
140
50 – 100
280
101 – 150
420
B.3 InstALLInG thE mAjoLIcA sIdE pAnEL tILEs
upon delivery the majolica lining on the left and right hand side of the units are
not mounted.
The, in total, six ma�olica tiles side lining needs to be positioned carefully by sliding
the tiles down the two vertical sliding rails. start with the bottom tile, end with the
top tile. see picture 5 up to picture 9.
position the two majolica supports first at both sides of the stove, see picture 3 and 4.
a = majolica support, B = majolica support adjustable feet, c = adjustable feet
arabella stove.
When after positioning all the majolica tiles the seams between the tiles are for
example not symmetrical, the height of the Ma�olica tiles in relation to the stove
itself can be changed by using the majolica support adjustable feet B.
Picture 5, Positioning
the bottom tile
Picture 6 Positioning
the middle tile
Picture 7 Positioning
the top tile
Picture 3: positioning of
the majolica supports
Picture 4: positioning of
the majolica supports
A
B
B
c
c
A
B
B