Without the 'SAVE' setting your heater will maintain the set temperature by

approximation as well, by adjusting its heating capacity. 'SAVE' is an economy

setting, which you can use when, for instance, you are not present in the room

or to keep it frost-free.

K

THE 'FUEL' INDICATOR

When the FUEL indicator appears, there is enough fuel left for another 10 minutes

of heater use. The count-down of the remaining heating time can be seen in the

information display 

M

(Fig. J). Every two minutes an alarm signal is sounded,

warning you to refill the removable tank. If you do not react, the heater will

extinguish by itself. The heater will also sound a warning signal, when it switches

off. The FUEL indicator will blink, while four lines are blinking in the information

display. You can stop this by pressing the 

button 

N

once.

Once the heater has used up all its fuel and is extinguished it will take some time,

after the refill, before the heater is completely ready for use again.

L

THE 'VENT' INDICATOR

When there is insufficient ventilation in the room, an intermittent buzzer will be

heard (approximately once each 30 seconds) and the VENT indicator will be lit. When

this signal is given, ensure that the ventilation of the room is improved (e.g. by

opening a door or window a little more), to avoid that the heater shuts off. When the

ventilation of the room is improved, the VENT indicator and buzzer will be

deactivated. When there is still insufficient ventilation, the heater shuts off

automatically. When this occurs,  

e -1 1

is displayed and the VENT indicator is blinking.

After improving the ventilation of the room (e.g. by opening a door or window a little

more), the heater can be ignited by pushing the 

button 

N

again.

M

MAINTENANCE

Switch off the heater and let it cool down, before you start any maintenance

work. Also disconnect the plug from the mains. Your heater needs hardly any

maintenance. It is, however, important that you clean the air filter 

I

and the vent

filter 

J

with a vacuum cleaner and the grid 

with a damp cloth, both on a

weekly basis. Remove the air filter occasionally (Fig. L) and clean it with soapy

water. Prior to reinstallation, make sure that the air filter cap has fully been dried. 

Regularly inspect the fuel filter as well:

Remove the removable tank 

7

from the heater and remove the fuel filter 

(Fig. M). Some drops may leak from the filter; keep a cloth at hand.

Remove the dirt by tapping the fuel filter upside-down against a hard surface. 

(Never clean it with water!)

Reinstall the fuel filter into the heater.

We recommend that you remove dust and stains from time to time with a damp

cloth, because otherwise these may cause stains that are hard to remove.

3

2

1

4

49

M

L

Fuel filter

K: A blinking VENT

indicator is a sign that

you need extra

ventilation.

J: When the FUEL

indicator has appeard,

the information display

will show the number of

minutes of fuel left in 

the tank.

Summary of Contents for SRE 150 E

Page 1: ...SRE 150 E 2 12 22 32 42 52 62 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING 3 2 6 5 4 1...

Page 2: ...les produits de combustion Contr le de la qualit de la combustion absence de CO Endurance Intermittence CONSEILS D UTILISATION ET D ENTRETIEN Se reporter la notice jointe l appareil et la plaque de s...

Page 3: ...e first to ensure maximum lifetime for your Zibro heater Your heater comes with a 24 month manufacturer s warranty on all defects in materials or workmanship We wish you a warm and comfortable time wi...

Page 4: ...aining fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Fuel gauge removable tank Air filter Vent filter Thermostat Plug cord...

Page 5: ...room is smaller than the specified space always put a window or door slightly ajar 2 5 cm We also recommend doing this in highly insulated or draught free rooms and or at altitudes above 1 500 metres...

Page 6: ...d set the correct time using the adjustment keys P refer to Section C Your heater is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place the...

Page 7: ...set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Always ignite the heater with the butto...

Page 8: ...ff the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button N once to clear the timer setting G SWITCHING OFF THE HEATER There are tw...

Page 9: ...eans When the burner is clean again the heater will automatically switch back to the highest setting again I CHILDPROOF LOCK The childproof lock can be used to prevent children accidentally changing t...

Page 10: ...is improved the VENT indicator and buzzer will be deactivated When there is still insufficient ventilation the heater shuts off automatically When this occurs e 1 1 is displayed and the VENT indicato...

Page 11: ...e filter keep a cloth at hand Store the fuel filter and the removable tank outside the heater Place the transportation cap into the position of the fuel filter Fig N Press it tight Always move the hea...

Page 12: ...n never try to move the heater but always switch off the heater immediately In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher...

Page 13: ...E E E E E E E E E E E E E E E E E E E E E E E E M N A E G F D K B C J L I H Q P E P R O S...

Page 14: ...zibro com SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old B...

Reviews: