Remove the removable tank
7
from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand.
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(Never clean it with water!)
Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains in time with a damp cloth,
because otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your Zibro
dealer for repairs. When the power cord is damaged, it may only be replaced
by an authorised fitter. Use a new cord of the type H05 VV-F.
N
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste. Always start the new
heating season with fresh fuel. When you start re-using the heater follow the
instructions again (starting from section A and as specified).
O
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
Let the heater cool down.
Remove the removable tank
G
from the heater and remove the fuel filter
(refer to Section M, Fig. N). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
Place the transportation cap into the position of the fuel filter (Fig. O).
Press it tight.
Always move the heater in an upright position.
P
SPECIFICATIONS
SRE240E/SRE246E
Ignition
electrical
Dimensions (mm)
width
550
Fuel
paraffin
(including base plate) depth
328
Capacity (kW) max.
4.00/4.65
height
445
Capacity (kW) min.
1.05/1.45
Accessories manual fuel pump
Suitable space (m
3
)
**
65-170/75-190
transportation cap
Fuel consumption (l/hr)
*
0.417/0.484
Mains
230V
Fuel consumption (g/hr)
*
333/388
-- AC/50 Hz
Burning time per tank (hr)
*
18.2/15.7
Electrical consumption
igniter 320
W
Capacity removable tank (litres) 7.6
continuous 29W/31W
Weight (kg)
12.0/13.5
Fuse rating
250V, 5A
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
-sensor E-Guard
).
* At maximum setting ** Specified values are indicative
4
3
2
1
3
2
1
4
58
transportation cap
☞
O
Fuel filter
N