64
Picture 12
Picture 13
Picture 14
Picture 15
Picture 16
d.3.7 cleaning the fume gas outlet pipe
This stove is provided with 2 potential flue gas outlet pipe connection possibilities.
Either the outlet can be placed on top, or the outlet can be placed at the back side.
Always make sure that the opening which is not used is closed securely.
Clean the fume gas outlet pipe internally twice per year. This needs to be done by a by
Zibro authorized installer.
First: disconnect the chimney from the stove.
Picture 17
Picture 18
Picture 19
To clean the back side flue gas outlet
1. Remove the cap (only when top outlet is used) (See picture 17)
2. Clean the internal stove pipe with a cylindrical brass brush and a vacuum cleaner. See
picture 18.
3. Replace the closing cap. (see picture 17) (only when a top outlet is used)
To clean the Top side flue gas outlet
1. Remove the top cover plate (refer to chapter D.3.2, see picture 19)
2. Remove the flue gas cap (only when back side outlet is used)
3. Clean the internal stove pipe with a cylindrical brass brush and a vacuum cleaner. See
picture 18.
4. Replace the closing cap (only when a back side outlet is used)