background image

 

Distance & Spot size 

As the distance (D) from the object increases, the spot size (S) of the area measured by the unit 
becomes larger. The relationship between distance and spot size for each unit is listed below. 

 

The distance to target / size of IR focal spot ratio is 12:1. With a distance of 12 cm to the target, 
•the size of the IR focal spot is thus 1 cm. 

 

Note: 

Field of View: Make sure that the target is larger than the unit’s spot size. The smaller the target, 
the closer you should be to it. When accuracy is critical, make sure the target is at least twice as 
large as the spot size. 

 

SPECIFICATIONS 

-50 to 500 

 (-58

 ~ 932

)

 

Temperature range

 

12

1

 

D: S

 

0.1 

 (0.1

)

 

Display resolution

 

Fixed at 0.95

 

Emissivity

 

for targets: 
±3

(5.4

±2.0% ±2

(

3.6

)

 

Accuracy 
-50 ~ 20

(-58

 ~ 68

)         

20

 ~500

(68

 ~932

)                                               

±1

(1.8

)             

 

Repeatability

 

500ms

 

Response time                                                                         

8~14um

 

Spectral response                                                                 

LCD will show “----”

 

Over range indication                                                   

output <1mW, Wavelength 630~670nm, 
Class 2 laser product

 

Diode laser                                                           

 

0 to 50

(32 to 122

)

 

Operating temp.                                                   

–10 to 60

 (14 to 140

)

 

Storage temp.                                                       

10%~90%RH operating,

 

<80%RH storage 

Relative humidity                                                                 

9V  battery,  NEDA  1604A  or  IEC  6LR61,  or 
equivalent

 

Power supply                                             

 

 

 

 

 

 

Summary of Contents for ZI-9679

Page 1: ...cts which are uneasy to be touched Proper use and care of this meter will provide years of reliable service FEATURES Rapid detection function Precise non contact measurements Single laser sighting Unique flat surface modern housing design Automatic Data Hold MAX MIN function Wide range application Food preparation Safety and Fire inspectors Plastic molding Asphalt Marine and Screen printing measur...

Page 2: ...target the closer you should be to it When accuracy is critical make sure the target is at least twice as large as the spot size SPECIFICATIONS 50 to 500 58 932 Temperature range 12 1 D S 0 1 0 1 Display resolution Fixed at 0 95 Emissivity for targets 3 5 4 2 0 2 3 6 Accuracy 50 20 58 68 20 500 68 932 1 1 8 Repeatability 500ms Response time 8 14um Spectral response LCD will show Over range indicat...

Page 3: ...3 Panel description Button instruction 1 Power on Measure button automotive switch off about 10 seconds 2 Laser Backlight button 3 C F 4 Max Min button 5 Display screen ...

Page 4: ...n the LCD indicating that the reading is being held In HOLD status press the MAX MIN button to display maximum and minimum measurement points in the last measure The meter will automatically power down after approximately 10 seconds without use Switching C F Short press the C F button Switching Max Min Press the Max Min button Switch on off laser and backlight Short press the Laser Backlight butto...

Page 5: ...ver back Note In case of long term storage is recommended to remove the battery Last date to use mention on the battery Battery provided with the instrument is Non rechargeable battery Keep all batteries away from children and animals swallowing a battery can be fatal in which case you should seek immediate medical attention Keep batteries away from direct sunlight high temperature and high humidi...

Reviews: