Working method

The ZIEGRA chip-ice machine is delivered ready for operation and has only to be connected to power and water supply.

No operating personnel is required.
The machine works fully automatically.

Water flows by gravity from the water chamber in the ice-
machine into the freezing cylinder. An evaporating coil

(e.g. R404) surrounds the cylinder, freezing the water inside
at an evaporation temperature of -20° C up to - 30° C.

An auger continuously scrapes thin layers of ice from the
inner cylinder wall and conveys it upwards. There the ice
is compacted, frozen further and subsequently broken off.

By this procedure the refrigeration energy can freeze the followig water without loss.
If the ice layer would become 1 or 2 mm thick, an unnecessary amount of energy would have to be used for freezing
due to the high insulating capacity of ice.

 

The

 ideal ice thickness of 6 - 9 mm

 at low energy consumption can be achieved thanks to the idea of subsequently 

compacting the ice.

The ice being frozen on the inner wall of the cylinder, the refrigeration system of ZIEGRA Chip Ice Machines 
is completely sealed. The rotating auger does not form part of the refrigeration circuit.

Therefore leakages in the refrigeration system caused by rotating parts cannot occur.

The ideal ice temperature is  -0,5° C

ZIEGRA Chip-ice has the ideal temperature of - 0,5° C .

It is irregular and crystalline in structure and always stays loose.
In contrast with other types of ice it can be stored without being sub-cooled and never freezes up.

ZIEGRA-Cip-Ice

 is frozen within the patented freezing cylinder at an evaporation temperature of -20° C up to -30° C.

Due to the special procedure maximum refrigeration capacity is obtained at a very low energy consumption.

Cooling energy:

The uninterupted line shows the accumulated energy per kg of ice
(refrigeration energy). 
Only when ice having a temperature of 0° C
melts to water of 0° C, the considerable  

Refrigeration Capacity  of                   

80 Kcal / kg

is released (vertical line)

The cooling capacity of water per °C is 
(left line)

  1 Kcal / kg,

Ice tempeartures below 0° C give only

0,5 Kcal / kg.

Energy consumption:

The broken line shows the minimum electric energy consumption
necessary for every ice production.
For an ice temperature of 0° C energy input and the 
refrigeration capacity produced are closely correlated.
Only when ice is unnecessarily cooled to temperatures below 0° C,
the energy required rises disproportionately.

1

Summary of Contents for 1.750

Page 1: ...ce quality Miscellaneous 7 Cleaning of freezing unit 8 Wiring diagram attached Cooling circuit General installation advice Assembly Instruction Freezing Unit Spare parts list Subject to technical modifications 6 07 ZIEGRA EISMASCHINEN Germany 30901 Isernhagen www ziegra com Service Tel 49 511 90244 0 Tel 49 511 90244 14 Fax 90244 90 Fax 90244 92 ice ziegra com service ziegra com UBE ZBE SWE SI TW ...

Page 2: ...otating auger does not form part of the refrigeration circuit Therefore leakages in the refrigeration system caused by rotating parts cannot occur The ideal ice temperature is 0 5 C ZIEGRA Chip ice has the ideal temperature of 0 5 C It is irregular and crystalline in structure and always stays loose In contrast with other types of ice it can be stored without being sub cooled and never freezes up ...

Page 3: ...f the machine Tighten all electrical connections in the control and at water temperatures above 15 C resp 25 C panel as they may have loosened during the production capacity may decrease transport Crankcase heater 3 Water connection After connecting the machine to electricity the start up is possible only after abt 1 hr The machine works with normal potable water Preheating see page 3 point 9 With...

Page 4: ...is full This light barrier has been chosen by us for these 10 Phase sequence Relay particular conditions Please contact us The phase sequence relay switches off the machine if the phases are not connected in the c Other cut off devices correct order see electrical connection Also when the ice is produced directly in an ice car a cut off device should be installed 11 Low voltage relay Please contac...

Page 5: ... if necessary V belts check replace if necessary A loose V belt does not transfers the load correctly on the auger This will overload the freezing unit Ice hose and water retainer calcified clean or replace Gearbox ATM NRV 90 Lifetime lubrication with synthetic oil 1 Litre check oil level or Flender OT 80 Lifetime lubrication with synthetic oil 1 5 Litre detach drive shaft cover BP Energol SGXP 22...

Page 6: ...heck connection and fuses Fuses blow up Check Intermittent contact Check electrical connections also in control panel Water pressurestat or readjust or replace Water level control defective readjust or replace Ice jam switch has cut off eliminate cause reset switch manual reset of machine Light barrier does not work check see page 6 Voltage too low or too high Voltage as per type plate max 5 min 1...

Page 7: ... cooled machine insufficient water pressure increase water pressure to min 2 bar condenser soiled clean condenser with bottle brush hot water and antilime agent clean water filter water or condensing pressure check clean replace governor misadjusted soiled or defective Cut out by compressor compressor overheated depending on ambient temperature let machine cool for 3 hours compressor starts again ...

Page 8: ...just evaporation temperature as indicated Check thermal feeler pipe and contact at evaporator outlet insufficient amount of refrigerant remove leak evacuate circuit refill bubbles in sight glass with indicated quantity of refrigerant lime deposit on auger or cylinder clean freezing unit see page 8 machine has switched off also consider possible water shortage in between times or malfunction with a...

Page 9: ...g unit into a container o Connect a hose of appr 80 cm with funnel at the water inlet of the freezing unit o Mix cleaning agent with hot water For each freezing unit 1 2 bottle agent in 1 litre water of appr 50 C o Fill the freezing unit with cleaning agent up to the ice discharge level o Allow the cleaner to react for 10 15 minutes This is mostly sufficient A maximum of 30 minutes must not be exc...

Reviews: