For devices > 16A and
≤
75A according to EN61000-3-12 (see Electrical Installation /
Harmonics current and line impedance)
Please ask manufacturer for the individual harmonic oscillation levels of the current as
a percentage of the fundamental oscillation of the rated current.
Vibratory strength
(for vertical installation, i.e. cable inlet
down).
FXDM2.5(A)M...22(A)M and FXDM32(A)ME...50(A)ME
Broadband noise (simulated life-endurance test) in accordance with EN 61373, cat-
egory 1 class B.
Shock test according to EN 61373, category 1
*
Regarding the mains connection, these devices are to be classi
fi
ed as category
“
C2
”
devices according to the relevant
DIN EN 61800-3. The increased requirements placed on electrical interference > 2 kHz for category
“
C1
”
devices are
complied with in addition.
14.1.1
Versions type-lines Fcontrol
In IP54 for wall mounting
•
FXDM..
external terminal type AXG-1A(E), for start-up and setting necessary.
•
FXDM..A
internal LCD-Multifunction display with plain language text.
In IP20 for switch cabinet mounting
•
FXDM..E
external terminal type AXG-1A(E), for start-up and setting necessary.
•
FXDM..AE
internal LCD-Multifunction display with plain language text.
14.1.2
Max. load dependent on ambient temperature and line voltage.
The maximum permissible temperature for the rated current at rated voltage is speci
fi
ed as rated
temperature.
Since the dissipation of the power loss (heat development) in the device is decisively dependent on
the ambient temperature, the max. load must be reduced at an ambient temperature above the rated
temperature (see following table)!
The average value measured during a 24 h period must be 5 K under the max. ambient temperature.
For installation in a switch cabinet, the device
’
s dissipation and its possible affect on the ambient
temperature must be taken into consideration!
Since the power loss in the device increases with rising line voltage, the following table must be
observed.
Type
Maximal load depending on line voltage and ambient temperature
208 V (-15 %)...415 V (+6 %)
over 415 V (+6 %)...480 V (+10 %)
40
°
C
50
°
C
55
°
C
40
°
C
50
°
C
55
°
C
FXDM2.5(A)M
2.5 A
2.0 A
1.5 A
2.2 A
1.5 A
1.2 A
FXDM5(A)M
5.0 A
5.0 A
4.2 A
5.0 A
5.0 A
4.0 A
FXDM8(A)M
8.0 A
8.0 A
7.5 A
8.0 A
8.0 A
7.0 A
FXDM10(A)M
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
10.0 A
FXDM14(A)M
14.0 A
12.0 A
11.0 A
14.0 A
12.0 A
10.5 A
FXDM18(A)M
18.0 A
16.0 A
12.0 A
18.0 A
15.0 A
11.5 A
FXDM22(A)M
22.0 A
18.0 A
15.3 A
22.0 A
17.0 A
14.5 A
FXDM32(A)M(E)
32.0 A
32.0 A
30.0 A
32.0 A
32.0 A
30.0 A
FXDM40(A)M(E)
40.0 A
40.0 A
37.0 A
40.0 A
40.0 A
35.0 A
FXDM50(A)M(E)
50.0 A
50.0 A
48.0 A
50.0 A
50.0 A
46.0 A
Operating Instructions
Fcontrol
–
model series FXDM
Enclosure
L-BAL-E072-GB 1642 Index 008
Part.-No.
99/105