8
Enclosure
8.1
Technical data
Type
(Part-No.)
Rated cur-
rent
Output
{1}
[A]
Rated cur-
rent
(
I
fundamen-
tal compo-
nent @
50 Hz)
Input
{2}
[A]
Recommen-
ded motor
output
{3}
[kW]
Rated tem-
perature
[
°
C]
max. line
fuse
{4}
[A]
max. heat
dissipation
{2}
[W]
Weight
[kg]
FSDM2.6
(308214)
2.6
2.6
(2.4)
1.1
50
6
40
2.5
FSDM3.6
(308215)
3.6
3.4
(3.1)
1.5,
40
6
55
2.6
FSDM5
(308216)
5.0
4.8
(4.5)
2.2
55
10
80
4.6
FSDM7
(308217)
7.0
6.4
(6.0)
3.0
50
10
105
4.7
FSDM8.5
(308218)
8.5
7.8
(7.2)
4.0
55
10
130
5.6
FSDM12
(308264)
12.0
11.0
(9.9)
5.5
55
16
175
5.7
FSDM17
(308269)
17.0
15.3
(14.1)
7.5
50
20
260
5.9
FSDM25
(308322)
25.0
25.0
(-)
11
40
35
480
12.3
FSDM32
(308324)
32.0
27.6
(25.7)
15
50
35
750
24.3
FSDM39
(308326)
39.0
34.0
(31.5)
18.5
55
50
900
26.1
FSDM46
(308328)
46.0
46.0
(-)
22,0
50
50
1050
26.1
FSDM62
(308330)
62.0
62.0
(-)
30,0
40
63
1250
26.1
{1}
Rated current output
current indication rating plate @ rated voltage, @ rated temperature (cos
φ
0.8 at the output).
{2}
At rated voltage (cos
φ
0.8 at the output), values for different speci
fi
cations on request.
{3}
Example for power of a 4 pole motor. For the dimension of the frequency inverter size the rated current of the motor is
crucial!
{4}
Max. line fuse on site (line protection fuse) according to EN 60204-1 Classi
fi
cation VDE0113 Part 1 (see also Assembly
instructions / Electrical installation / Mains connection / Line protection fuse).
Line voltage*
3 ~ 208...480 V (-15 up to +10 %), 50/60 Hz
Nominal voltage
400 V
Maximal output voltage
approx. 95 % from U
Line
Maximal output frequency
50 Hz (1 - 120 Hz) **
Edgefrequency
50 Hz (1 - 120 Hz) **
U/f-characteristic curve
linear (quadratic) **
Switching frequency
8 kHz (10 / 16 kHz) **
Rating switching frequency
FSDM2.6...25: 8 kHz
FSDM32...62: 6 kHz
Rampup time
20 sec (1 - 250 sec) **
Rampdown time
20 sec (1 - 250 sec) **
Current limit
120 % (100 - 130 %) **
Power factor
> 0.9
Operating Instructions
Icontrol Basic
–
model series FSDM2.6...62
Enclosure
L-BAL-E160-GB 1701 Index 004
Part.-No.