background image

1 General notes

1.1 Structure of the operating instructions

Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to speci

c units only, and 

are in no way valid for the complete system!

Use these operating instructions to work safely with and on the device. They contain 
safety instructions that must be complied with as well as information that is required for 
failure-free operation of the device.
Keep these operating insturctions together with the device. It must be ensured that all 
persons that are to work on the device can refer to the operating instructions at any time.

1.2 Exclusion of liability

To allow for future developments, construction methods and technical data given are 
subject to alteration. We do not accept any liability for possible errors or omissions in the 
information contained in data, illustrations or drawings provided.
We accept no liability for damage caused by misuse, incorrect use, improper use or as a 
consequence of unauthorized repairs or modi

cations.

1.3 FCC / IC Statements

FCC Compliance (US)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two conditions:(1) this device may not cause harmful interference, and(2) this device 
must accept any interference received, including interference that may cause undesired 
operation.

Note: This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction manual, 
may cause harmful interference to radio communications. Operation of this equipment in 
a residential area is likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.

FCC Warning

Changes or modi

cations not expressly approved by the party responsible for compli-

ance could void the user's authority to operate the equipment.

IC Compliance (Canada)

This device complies with Industry Canada licence-exempt RSS standard(s). Operation 
is subject to the following two conditions: (1) this device may not cause interference, and 
(2) this device must accept any interference, including interference that may cause 
undesired operation of the device.

Operating Instructions 

 A-G-247NW

 

General notes

L-BAL-E184-GB 1309 Index 002

Part.-No. 00163401-GB

3/21

Summary of Contents for A-G-247NW

Page 1: ...A G 247NW Part No 380090 Hand held terminal Operating Instructions Software version from Version 8 05 L BAL E184 GB 1309 Index 002 Part No 00163401 GB english...

Page 2: ...tion 9 5 1 Display and operating elements of the terminal 9 6 Programming 10 6 1 Overview mainmenu 10 6 2 AM MODBUS App s 11 6 2 1 Con guration Online 11 6 2 2 Auto Addressing 12 6 2 3 Load Paramterse...

Page 3: ...onditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has bee...

Page 4: ...ion commissioning and maintenance and servicing in connection with the device must have the corresponding quali cations and skills for these jobs In addition they must be knowledgeable about the safet...

Page 5: ...inal s USB interface Information The terminal software is continuously developed and improved Ziehl Abegg will provide free rmware upgrades for downloading in future 3 2 Storage The device must be sto...

Page 6: ...upply of the terminal is made by the internal accumulators or the plug power supply unit The device switches off automatically if the plug power pack is left connected with fully charged batteries and...

Page 7: ...D B D GND and ID1 ID2 Information You must ensure correct connection i e A D must also be connected on the following devices to A D The same applies to A D In addition a GND connection must be establi...

Page 8: ...location A D red B D black ID1 ID2 yellow GND white Default interface parameter Baudrate 19200 Bits 8 Parity Even Stop bits 1 Handshake none Information If any matters are unclear please contact our V...

Page 9: ...arged full 9 Selection option of the sub menu display in menu language English 10 Key not assigned soft key program dependent function Explanation of display menu User 04 05 2009 v_display_erkl_a g 24...

Page 10: ...rsion 9 00 AM PREMIUM App s P P P Con guration online RS 485 Programming of devices with integrated universal control module AM PREMIUM RS 485 Wireless Programming of devices with integrated universal...

Page 11: ...ith the P key for the rst connection For members with changed addresses set these from 001 to 246 with the keys and con rm with the P key to make the connection RF Network Key Radio control key only f...

Page 12: ...isation are considered operating manual AM MODBUS PIN 0010 Opening service menu Controller Setup IO Setup Motor Setup for programmed access level 2 PIN 1234 Opening user menu Setting for programmed ac...

Page 13: ...AM MODBUS W wire less Device Count Enter the number of devices max 64 with the keys and con rm with the P key If the automatic addressing was performed rst the number of detected devices is taken ove...

Page 14: ...menu with P key Interface Select type of interface with the keys and con rm with the P key RS 485 Programming of devices with integrated universal control module AM PRE MIUM RS 485 Wireless Programmin...

Page 15: ...ation of Ziehl Abegg devices with RS 485 MODBUS interface without built in Add on module AM MODBUS W or AM PREMIUM W Alternatively to the use of an external terminal type AXG 1A E AXG Mode Open menu w...

Page 16: ...ayed The CSV folder contains the tables with the parameter sets saved in the terminal Example ECBLUEX CSV TEST01 CSV TEST02 CSV These can be copied to the PC for backup and administration A parameter...

Page 17: ...put RS 485 Select device 002 Files Start Download Files ECBLUEX CSV TEST01 CSV TEST02 CSV TEST03 CSV Parameterset IXI AM MODBUS APP s AM PREMIUM App s AXG Mode USB Filetransfer USB COMPORT A G 247NW S...

Page 18: ...nection to the USB interface on the PC Follow the further instructions on the screen until installation is complete USB VIirtual COMPORT Connecting Mini B 5 pin USB 01 03 2013 v_a g 247_comport VSD AM...

Page 19: ...247NW Device name Display of device name and software version A G 247NW Setup P Display 0 Light at Battery Lighting intensity in battery operation Setting range 0 10 0 without background lighting 10...

Page 20: ...mission according EN 61000 6 3 domestic household applications Interference immunity according 61000 6 2 industrial applications Only in connection with the plug power pack supplied by Ziehl Abegg Plu...

Page 21: ...our V STE support department for control systems ventilation technol ogy Our worldwide contacts are available in our subsidiaries for deliveries outside of Ger many www ziehl abegg com If you make re...