2.2 Explanations of symbols

Safety instructions are highlighted with warning triangles and are depicted according to the degree of

hazard as follows.

Attention!

Hazardous area. Death or severe injury or signi

cant property damage can occur if the

corresponding precautions are not taken!

Danger owing to electric current

Danger owing to electric current or voltage.

Information

Important information and advice for user.

2.3 Product safety

The device conforms to the state of the art at the time of delivery and is fundamentally considered to

be reliable. The device and its accessories must only be used in a

awless condition and installed and

operated in compliance with the assembly instructions and/or operating instructions. Operating out-

side the device's technical speci

cations (

F

rating plate and attachment / technical data) can lead to a

defect in the device and additional damage!

In the case of a malfunction or a failure of the equipment check all functions with alarms in

order to prevent injury to persons or property. Note possibility of back-up operation. If used in

intensive animal environments, any malfunctions in the air supply must be detected as soon

as possible to prevent the development of a life-threatening situation for the animals. The

design and installation of the system must comply with local regulations and directives. In

Germany these include DIN VDE 0100, the animal protection and the keeping of working

animals ordinance and the pig-keeping ordinance etc. Also note the instructions of AEL, DLG,

VdS.

2.4 Requirements placed on the personnel / due diligence

Persons entrusted with the planning, installation, commissioning and maintenance and servicing in

connection with the frequency inverter must have the corresponding quali

cations and skills for these

jobs.

In addition, they must be knowledgeable about the safety regulations, EU directives, rules for the

prevention of accidents and the corresponding national as well as regional and in-house regulations.

Personnel to be trained or instructed and apprentices are only permitted to work on the device under

the supervision of an experienced person. This also applies to personnel undergoing general training.

Comply with the legal minimum age.

2.5 Start-up and during operation

Attention!

During commissioning, unexpected and hazardous conditions can arise in the entire installation due to

defective adjustments, defective components or incorrect electrical connections. Remove all persons

and objects from the hazardous area.

During operation, the device must be closed or installed in a control cabinet. Fuses may only be

replaced by new ones and must not be repaired or bypassed. The data for the maximum line fuse are

to be considered absolutely (

F

Technical data). Use only fuses speci

ed in schematic diagrams.

Any faults detected in the electric system/modules/operating equipment must be corrected

immediately. If these faults are not corrected, the device/system is potentially very dangerous. The

device/system must therefore not be operated when it is faulty.

Operating Instructions

Acontrol

model series PKE-6 /-10 / PKE-14

Safety information

L-BAL-E042-GB 1002 Index002

Part.-No. 00163314-GB

4/26

Summary of Contents for Acontrol PKE-6

Page 1: ...ntrol PKE 6 10 PKE 14 P controller and speed controller for variable voltage 1 fans Operating Instructions Software version D1361A from Version 00 L BAL E042 GB 1002 Index 002 Part No 00163314 GB engl...

Page 2: ...uences during commissioning 7 5 Electrical installation 8 5 1 Safety precautions 8 5 2 EMC compatible installation 8 5 2 1 Motor feeder cable 8 5 2 2 Signal cable 8 5 3 Mains connection 8 5 4 Motor co...

Page 3: ...mperature control Heating function 17 9 3 Pressure control condensers P Controller 3 01 18 9 3 1 Setting for operation as Pressure controller 18 9 3 2 Example Pressure control condensers 18 9 3 3 Sett...

Page 4: ...illustrations or drawings provided Ziehl Abegg AG is not liable for damage due to misuse incorrect use improper use or as a consequence of unauthorized repairs or modi cations 1 4 Copyright These oper...

Page 5: ...Also note the instructions of AEL DLG VdS 2 4 Requirements placed on the personnel due diligence Persons entrusted with the planning installation commissioning and maintenance and servicing in connec...

Page 6: ...tractor or owner must also ensure that the electric systems and equipment are operated and maintained in accordance with electro technical regulations The owner is obliged to ensure that the device ar...

Page 7: ...e on a clean and stable base Do not distort during assembly Use the appropriate mounting devices for proper installation of the unit Do not mount equipment on vibrating base When mounted onto lightwei...

Page 8: ...arance or thermal shielding is required 4 3 Outdoor installation Outdoor installation is possible up to 20 C when the controller supply is not switched off Installation must be protected from the effe...

Page 9: ...astic housing parts because there is no potential equalization Never clean electrical equipment with water or similar liquids Information The respective connections are represented in the enclosure of...

Page 10: ...ection is required We cannot under any circumstances accept liability for damage to the motors which do not have the required motor protection It is recommended that every fan is equipped with a separ...

Page 11: ...ted Attention No disconnection isolation when turned off in accordance with VBG4 6 Never apply line voltage to the digital input It is not permissible to connect inputs of several devices to each othe...

Page 12: ...over n max Potentiometer n max Pband Function dependently on selected mode of operation For speed controller 1 01 Maximal output voltage speed limiter Setting range 100 n min 100 output voltage fully...

Page 13: ...tches Attention Setting of jumper and switches not under voltage Observe the safety notices Changed functions become active partly only after renewed switching on the mains voltage E1 Analog In factor...

Page 14: ...tch S1 Position factory setting for all dipswitches OFF DIP Function OFF ON 1 Selection Speed controller P Controller Speed controller P Controller 2 Minimum speed cut off OFF ON 3 Type of Signal 0 10...

Page 15: ...ON OFF approx 2 5 of 100 set value nM 50 100 I Min Min 35 Max 100 20 C S 7 K R 27 C 2 0 K 10 05 2007 v_min_luft_abschalt vsd Minimum speed cut off idealized principle diagram nM Motor speed S Setpoin...

Page 16: ...priority if over n max 28 08 2008 v_nmax_pband_pke VSD n max P band R 4 9 5 30 n max Pband Maximal output voltage speed limiter Setting range 100 n min 100 output voltage fully clockwise position 30 9...

Page 17: ...mperature control with passive sensors TF KTY Setting range 0 100 26 76 C measuring range of controller Scale 0 100 26 76 C for Temperature control with passive sensors TF KTY set 0 5 10 15 20 25 30 3...

Page 18: ...C n min 35 Idealized principle diagram 9 2 3 Example Temperature control Heating function Val Set n DIP4 ON Temperature sensor type TF Measuring range controller 26 76 C Settings set 50 25 C 102 K 10...

Page 19: ...0 100 5 30 measuring range of sensor 0 100 n min R 4 8 28 08 2008 v_nmin_pke VSD n min Minimum output voltage basic speed Setting range 0 100 n min takes priority if over n max 9 3 2 Example Pressure...

Page 20: ...5 58 41 62 30 65 96 69 41 72 70 75 82 78 81 81 68 84 44 87 09 89 66 R401A C 29 21 6 93 6 40 16 33 24 39 31 26 37 28 42 68 47 59 52 10 56 29 60 22 63 91 67 40 70 72 73 88 76 91 79 81 82 60 85 29 87 99...

Page 21: ...r max imum signal values depending on selected signal type The device works with minimal or maximum modula tion depending on whether there is a short circuit or an interruption and on the programmed m...

Page 22: ...densation Electromagnetic compatibility for the standard voltage 230 400 V according to DIN IEC 60038 Interference emission EN 61000 6 3 domestic household applications Interference immunity EN 61000...

Page 23: ...KTY 4 1 E1 V mA C GND 24 V M 1 PE U1 U2 1 Motor ohne Thermostatschalter without thermostats 2 1 Line 1 230 V 50 60 Hz 2 1 Motor without thermostats 3 Output 0 10 V Imax 10 mA 4 Input 0 10 V 2 10 V 0...

Page 24: ...reglerad spanning 1 60V 250V 50 60Hz 1 2 4 6 12 11 24 23 Option ZB ZK 2S Kontaktbelastung der Hilfskontakte contact rating of auxiliary contacts pouvoir de coupure des contacts auxiliaires Kontaktbel...

Page 25: ...del series PKE 6 10 PKE 14 Enclosure L BAL E042 GB 1002 Index 002 Part No 00163314 GB 24 26 11 3 Dimensions mm PKE 6 PKE 10 PKE 14 Switch off the main supply before removing the cover Vor ffnen des De...

Page 26: ...tance 21 L line fuse 21 M mains is connected 8 mains voltage 8 maximum control current 9 MBG 30I 18 Minimum space requirement 7 Minimum speed cut off 14 Mode 12 motor feed cable 8 motor noise 9 motor...

Page 27: ...e information If you have any technical questions while commissioning or regarding malfunctions please contact our V STE support department for control systems ventilation technology Our worldwide con...

Reviews: