2.6 Work on the device
Information
Installation, electrical connection, and start-up operation may only be carried out by an
electrical specialist in accordance with electrotechnical regulations (e.g. DIN EN 50110 or DIN
EN 60204).
Danger owing to electric current
It is forbidden to carry out work on electrically live parts. The enclosure rating of the device
when open is IP 00! It is possible to inadventently touch components carrying hazardous
voltages!
The safe isolation from the supply must be checked using a
two-pole
voltage detector.
Attention!
Automatically restart after a power failure or mains disconnection!
2.7 Modi
cations / interventions in the device
Attention!
For reasons of safety, no unauthorized interventions or modi
cations may be made on the device. All
planned modi
cations must be authorized by the manufacturer in writing.
Use only genuine spare parts / genuine wearing parts / genuine accessories from Ziehl-Abegg.These
parts were speci
cally designed for the device. There is no guarantee that parts from non-original
sources are designed and manufactured in correspondence with load and safety requirements.
Parts and optional equipment not supplied by Ziehl-Abegg are not approved by Ziehl-Abegg for use.
2.8 Operator
’
s obligation of diligence
•
The contractor or owner must also ensure that the electric systems and equipment are operated
and maintained in accordance with electro-technical regulations.
•
The owner is obliged to ensure that the device are operated in perfect working order only.
•
The device may only be used as intended (
F
“
Application
”
).
•
You must periodically examine the safety equipment for their properly functioning condition.
•
The assembly instructions and/or operating instructions are always readily available at the
location where the device is being used, are complete and are in legible condition.
•
These persons are regularly instructed in all applicable questions regarding occupational safety
and environmental protection and are knowledgeable regarding the assembly instructions
and/or operating instructions and, especially, are familiar with the safety instructions contained
therein.
•
All safety and warning notices attached to the frequency inverter are never removed and remain
legible.
2.9 Employment of external personnel
Maintenance and service work are frequently carried out by external employees who often do not
recognize the speci
c situations and the thus resulting dangers.These persons must be comprehen-
sively informed about the hazards in their area of activity.
You must monitor their working methods in order to intervene in good time if necessary.
Operating Instructions
Acontrol
–
model series PKE-6 /-10 / PKE-14
Safety information