background image

1 General notes

Compliance with the following instructions is mandatory to ensure the functionality and 
safety of the product. If the following instructions given especially but not limited for 
general safety, transport, storage, mounting, operating conditions, start-up, mainte-
nance, repair, cleaning and disposal / recycling are not observed, the product may not 
operate safely and may cause a hazard to the life and limb of users and third parties.
Deviations from the following requirements may therefore lead both to the loss of the 
statutory material defect liability rights and to the liability of the buyer for the product that 
has become unsafe due to the deviation from the speci

cations. 

1.1 Structure of the operating instructions

Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to speci

c units only, and are in 

no way valid for the complete system!
Use these operating instructions to work safely with and on the device. They contain 
safety instructions that must be complied with as well as information that is required for 
failure-free operation of the device.
Keep these operating instructions together with the device. It must be ensured that all 
persons that are to work on the device can refer to the operating instructions at any time.
Keep the operating instructions for continued use. They must be passed-on to all 
successive owners, users and 

nal customers.

1.2 Target group

The operating instructions address persons entrusted with planning, installation, start-
up, maintenance and servicing, who have the corresponding quali

cations and skills for 

their job.

1.3 Exclusion of liability

Concurrence between the contents of these operating instructions and the described 
hardware and software in the device has been examined. It is still possible that non-
compliances exist; no guarantee is assumed for complete conformity. To allow for future 
developments, construction methods and technical data given are subject to alteration. 
We do not accept any liability for possible errors or omissions in the information con-
tained in data, illustrations or drawings provided. 
ZIEHL-ABEGG SE is not liable for damage due to misuse, incorrect use, improper use 
or as a consequence of unauthorized repairs or modi

cations.

1.4 Copyright

These operating instructions contain copyright protected information. The operating 
instructions may be neither completely nor partially photocopied, reproduced, translated 
or put on data medium without previous explicit consent from ZIEHL-ABEGG SE. 
Infringements are liable for damages. All rights reserved, including those that arise 
through patent issue or registration on a utility model. 

Operating Instructions 

Acontrol

 PSET6 / PSET10

General notes

L-BAL-E141-GB 1925 Index 004

Part.-No. 

4/24

Summary of Contents for Acontrol PSET6

Page 1: ...Acontrol PSET6 PSET10 Speed controller for variable voltage 1 fans Operating Instructions Keep for reference L BAL E141 GB 1925 Index 004 Part No english...

Page 2: ...2 9 Employment of external personnel 8 3 Product overview 8 3 1 Operational area 8 3 2 Maintenance 8 3 3 Transport 8 3 4 Storage 8 3 5 Disposal recycling 8 4 Mounting 9 4 1 General notes 9 4 2 Minimu...

Page 3: ...ions 16 6 3 Diagram setting signal and speed 16 6 4 Minimum speed cut off DIP 5 17 6 5 Hardstart function DIP 6 17 6 6 Operation with two variable output voltages two steps 17 7 Start up 18 7 1 Prereq...

Page 4: ...ating instructions at any time Keep the operating instructions for continued use They must be passed on to all successive owners users and nal customers 1 2 Target group The operating instructions add...

Page 5: ...arising from non intended use 2 2 Explanations of symbols Safety instructions are highlighted with warning triangles and are depicted according to the degree of hazard as follows Attention General haz...

Page 6: ...ulations Personnel to be trained or instructed and apprentices are only permitted to work on the device under the supervision of an experienced person This also applies to personnel undergoing general...

Page 7: ...e made on the device All planned modi cations must be authorized by the manufacturer in writing Use only genuine spare parts genuine wearing parts genuine accessories from ZIEHL ABEGG These parts were...

Page 8: ...The controller described is used for continuous speed adjustment on variable voltage 1 motors used to drive ventilators or pumps 3 2 Maintenance The device must be checked for soiling and if necessary...

Page 9: ...talled in a location where it will not be disturbed but at the same time can be easily accessed Depending on the housing model use supplied stoppers for cable inlets cut off necessary cable inlets res...

Page 10: ...f an electrician in accordance with electrical engineering regulations The 5 electrical safety rules must be observed It is forbidden to carry out work on electrically live parts Cover neighbouring el...

Page 11: ...onnect the shielding to one side only i e only to the control unit with the protective ground keep cable short and with as little inductance as possible 5 2 3 Harmonics current for devices 16 A Accord...

Page 12: ...r noise this noise may be dominant in the lower speed range due to the occurrence of resonance For systems where noise is critical we recommend using our Fcontrol series frequency converters with inte...

Page 13: ...ter factory setting DIP 8 ON 0 10 V modulation 0 100 Proportional the internal control of modulation with consideration n min and n max setting For enable OFF it goes not back to 0 V For motor fault t...

Page 14: ...ed Diagnostics faults Fault indicated for line fault blown internal semiconductor fuse broken controller internal voltage supply overheating by the motor thermostats TB connected When switching off vi...

Page 15: ...touch hazardous voltages directly 09 06 2011 v_pset_intern_bed VSD n max 0 100 n min 0 100 R15 ON OFF 10 9 8 7 6 5 4 3 2 1 DIP S1 R16 Potentiometer n min Minimal output voltage basic speed Setting ra...

Page 16: ...Analog Out 1 Constant voltage 10 V for exter nal potentiometer 0 10 V modulation 0 100 9 no function 10 no function 6 3 Diagram setting signal and speed Setting via external signal or external potenti...

Page 17: ...ng the mains voltage on the output voltage rises during the rmly programmed run up time to the given value DIP 6 ON Hardstart function ON For a safe starting of the connected fans the function Hard st...

Page 18: ...late will not be exceeded 5 Make sure that no persons or objects are in the hazardous area 8 Diagnostics Faults Operating states are indicated by both internal status LEDs by a ashing code Code Relay...

Page 19: ...de 09 06 2011 v_flash_code_pset VSD 2 1 ON OFF 8 1 If controller doesn t work correctly Information Setting of dip switches in principle only when device is not under voltage If the device is on mains...

Page 20: ...or current approx 0 2 A Voltage supply e g for sensors 24 V 20 Imax 250 mA Output 0 10 V Imax 10 mA short circuit proof Max permissible ambient tem perature 55 C Min permissible ambient tem perature 0...

Page 21: ...ature above the rated temperature see following table The average value measured during a 24 h period must be 5 K under the max ambient temperature For installation in a switch cabinet the device s di...

Page 22: ...ltern with internal thermostats 2 A1 GND Ausgang Output 0 10 V Imax 10 mA 3 E1 GND GND Eingang Input 0 10 V 4 PEUN17K4 08 06 2011 TB TB D1 D1 24V Kontaktbelastung Contact rating max AC 250 V 5 A 5 1 L...

Page 23: ...9 3 Dimensions mm PSET6 PSET10 Operating Instructions Acontrol PSET6 PSET10 Enclosure L BAL E141 GB 1925 Index 004 Part No 23 24...

Page 24: ...4 info ziehl abegg de http www ziehl abegg de 9 5 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical support for control...

Reviews: