background image

AM-LON

Part.-No. 349049

Communication module for ECblue fans

Operating Instructions

L-BAL-E166-GB 1610 Index 002

Part.-No. 00163375-GB

english

Summary of Contents for AM-LON

Page 1: ...AM LON Part No 349049 Communication module for ECblue fans Operating Instructions L BAL E166 GB 1610 Index 002 Part No 00163375 GB english ...

Page 2: ... 3 5 Disposal recycling 4 4 Mounting the module 5 5 Electrical installation 6 5 1 Safety precautions 6 5 2 Voltage supply 6 5 3 Communication 6 5 3 1 Connecting at the AM LON Modul 6 5 3 2 Wiring and terminating resistor in the LON network 7 6 Enclosure 8 6 1 Connection diagram 8 6 2 Manufacturer reference 9 6 3 Service information 9 Operating Instructions AM LON L BAL E166 GB 1610 Index 002 Part ...

Page 3: ... electrical connection and start up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations e g EN 50110 or EN 60204 Danger due to electric current It is generally forbidden to carry out work on electrical live parts Protection class of the device when open is IP00 It is possible to touch hazardous voltages directly The 5 electrical safety rule...

Page 4: ...inal packaging materials when transporting the device Avoid shocks and impacts to the device during the transport During manual handling the human lifting and carrying restrictions must be observed and adhered to 3 4 Storage The device must be stored in its original packaging in a dry and weather proof room Avoid exposure to extreme heat and cold Avoid over long storage periods we recommend a maxi...

Page 5: ...ing This applies regardless of whether the device is already connected to the line Equalize the potential again shortly before installation if the module is not installed immediately after unpacking After unpacking the module check for possible transport damage and insert it in the slot provided Do not touch the connection ECblue Mount the module in the housing with the two enclosed screws permiss...

Page 6: ...ected to terminals NET_A and NET_B The correct choice of cable is essential for the proper operation of the network Recommended wire types 22AWG twisted pair typical solid an unshilded Remote control line JY St Y 2x2x0 6 Wieland line system gesis con The connection of the LON bus is not polarity sensitive When using cable with more than two strands ensure that two twisted strands only are used for...

Page 7: ...e for routing reasons then free wiring can be used as an alternative Please note the restrictions on line length Information If any matters are unclear you can send for our technical information sheet Network structure of a LON TIL00_70 It contains information about the topology circuitry and selection of types of cable With free wiring i e no wiring rule is applied a terminating resistor of 50 Ω ...

Page 8: ...6 1 Connection diagram AM LON ID1 V ID2 MOLN07K0 15 03 2011 LON Service Pin max 5 VDC V LON Service Pin max 5 VDC B A B A Operating Instructions AM LON Enclosure L BAL E166 GB 1610 Index 002 Part No 00163375 GB 8 9 ...

Page 9: ...for control systems ventilation technology phone 49 0 7940 16 800 Email fan controls service ziehl abegg de Our worldwide contacts are available in our subsidiaries for deliveries outside of Ger many www ziehl abegg com If you make returns for inspections or repairs we need certain information in order to facilitate focused trouble shooting and fast repair Please use our repair tickets for this It...

Reviews: