Store the fan / motor in the original packaging in a dry area protected from the weather
and protect it from dirt and weather until
fi
nal installation.
•
Avoid prolonged storage; we recommend a maximum of one year (consult the
manufacturer before starting if stored for longer).
•
Inspect the bearing for proper operation prior to installation.
–
Recommendation: Turn the impeller evenly by hand to avoid jamming and damag-
ing the bearing.
•
Transport the fan(s) either in the original packaging or, in the case of larger fans, on
the dedicated transportation
fi
xtures.
–
axial fans: holes drilled in support arms, wall ring plates and motor block
–
centrifugal fans depending on type: holes drilled in the housing
fl
ange, motor
block, fastening brackets and support plates,
•
Radial impellers, fans with scroll RG.., RD.. or built-in fans type ER../GR.., WR.. are
generally delivered on europallets, and can be transported using lift trucks.
•
Design RG.. / RD.. / ER.. / GR../ WR../HR..
: Fan unit may only be lifted and
transported when using a suitable hoisting device (load spreader). Ensure su
ffi
cient
cable or chain length.
–
Design WR: lifting several fan units mounted on top of one another or next one
other is not permitted!
•
Design FV.. / DN..
: The fan must be fastened to 4 points during transport so the
fl
anges do not warp.
3.6 Disposal / Recycling
Disposal must be carried out professionally and in an environmentally friendly way in
accordance with the respective national legal stipulations.
"
Separate the materials by type and in an environmentally-friendly way.
"
If necessary, commission a specialist company with the waste disposal.
4 Mounting
4.1 General notes
Attention!
•
Mounting is only to be undertaken by trained service personnel. The system
manufacturer or the machine builder and/or the user is responsible that the inherent
installation and security information are harmonized with the valid standard and
guidelines (EN ISO12100 / 13857).
•
Check the fan for damage, e.g. cracks, dents or damage to the electric cables, before
assembly. Start-up is not allowed in the case of transport damage!
•
Wear safety clothing / shoes and cut-resistant safety gloves when handling!
•
At a weight greater than 25 kg for men / 10 kg for women, the fan should be lifted out
by two persons (according to REFA). The values may di
ff
er from country to country.
Assembly instructions
ECblue
Mounting
L-BAL-F056-GB 2022/45 Index 005
Part.-No. 00700562-GB
12/44