2.5 Requirements placed on the personnel / due diligence

Persons entrusted with the planning, installation, commissioning and maintenance and 
servicing in connection with the frequency inverter must have the corresponding qual-
i

cations and skills for these jobs.

In addition, they must be knowledgeable about the safety regulations, directives, rules 
for the prevention of accidents and the corresponding national as well as regional and in-
house regulations. Personnel to be trained or instructed and apprentices are only 
permitted to work on the device under the supervision of an experienced person. This 
also applies to personnel undergoing general training. Comply with the legal minimum 
age. 

2.6 Work on the device

Info

Mounting, electrical connection, and start-up operation may only be carried out by an 
electrical specialist in accordance with electrotechnical regulations (e.g. EN 50110 or 
EN 60204)!

Danger due to electric current

It is generally forbidden to carry out work on electrical live parts!

The 5 electrical safety rules must be observed!

The safe isolation from the supply must be checked using a 

two-pole

 voltage 

detector.   

Opening of motor is prohibited. Loosening the screws will void the warranty!

Any faults detected in the electric system/modules/operating equipment must be 
corrected immediately. If these faults are not corrected, the device/system is 
potentially very dangerous. The device/system must therefore not be operated when it 
is faulty.

Fuses must always be only replaced; never repaired or bridged. The speci

cations for 

the maximum series fuse must always be adhered to (

  Technical data). Only fuses 

cited in the electrical circuit diagram may be used. 

Attention, automatic restart!

The motor may switch on and o

 automatically for functional reasons.

Automatically restart after a power failure or mains disconnection!

Wait until the motor has stopped before approaching.

Danger of being sucked in!

Do not wear loose or hanging clothing, jewellery, etc., tie together long hair and cover it. 

2.7 Modi

cations / interventions in the device

Attention!

For reasons of safety, no unauthorized interventions or modi

cations may be made on 

the device. All planned modi

cations must be authorized by the manufacturer in writing.

Assembly instructions 

FE2owlet-ECQ

Safety instructions

L-BAL-F062-GB 2022/20 Index 004

Part.-No. 00702389-GB

7/24

Summary of Contents for FE2owlet-ECQ

Page 1: ...FE2owlet ECQ Motor size U EC fans with top ef ciency Assembly instructions Keep for reference L BAL F062 GB 2022 20 Index 004 Part No 00702389 GB english...

Page 2: ...e 7 2 8 Operator s obligation of diligence 8 2 9 Employment of external personnel 8 3 Product overview 9 3 1 Application operational area 9 3 2 Functional description 9 3 3 Motor protection 9 3 4 Note...

Page 3: ...servicing 17 7 2 Cleaning 18 8 Enclosure 18 8 1 Technical data 18 8 2 EC Declaration of Incorporation 20 8 3 UKCA Declaration of Incorporation 22 8 4 Manufacturer 24 8 5 Service address 24 Assembly i...

Page 4: ...its only and are in no way valid for the complete system Use these assembly instructions to work safely with and on the device They contain safety instructions that must be complied with as well as in...

Page 5: ...contained instructions especially the safety noti cations contained therein are considered part of intended use To consider is also the documentation of attached components 2 2 Improper use Improper...

Page 6: ...voltage Death or severe injury can occur if the corresponding precautions are not taken Info Important additional information and advice for user 2 4 Product safety The device conforms to the state of...

Page 7: ...m the supply must be checked using a two pole voltage detector Opening of motor is prohibited Loosening the screws will void the warranty Any faults detected in the electric system modules operating e...

Page 8: ...ons and or operating instructions are always readily available at the location where the device is being used are complete and are in legible condition These persons are regularly instructed in all ap...

Page 9: ...hree speeds rating plate Motors with three speeds Three pre programmed speeds are possible rating plate which are activated depending on the connection of the additional control input at L1 or N With...

Page 10: ...nical Data Pay attention to possible damage of the packaging or the equipment Store the fan motor in the original packaging in a dry area protected from the weather and protect it from dirt and weathe...

Page 11: ...ccidental contact is not necessary at the fan If the fan is located in danger zone then the manufacturer or operator shall ensure that hazards shall be prevented by appropriare protective constuctions...

Page 12: ...Permissible tightening torques MA Fastening element Central screw connec tion Fastening element for add on parts Motor fastening Material Steel Steel Plastic Motor size U Thread size M4 Property class...

Page 13: ...ation surfaces must be level 4 5 Connection of the motor Danger due to electric current The mains voltage must comply with the EN 50160 quality characteristics and the de ned standard voltages in IEC...

Page 14: ...h the brown wire the motor runs at speed step 3 If the black wire is connected with the blue wire the motor runs at speed step 2 If the black wire is not connected the motor runs at speed step 1 Dange...

Page 15: ...y closed according to the suitable installation position 6 Connection data complies with the speci cations on the rating plate During start up check the following 1 Check the rotat direction see the r...

Page 16: ...irection Motor turns in wrong direc tion at high speed Check air stream see Fan does not run Fan turns too slowly Impeller blade drags scrapes When indicated clear foreign bodies dirt from the fan Che...

Page 17: ...maintenance work at running fan Watch out for vibration free motion The impeller is subject to natural wear depending on the area of application and the conveying medium Deposits on the impeller can...

Page 18: ...ity for the standard volt age 230 400 V according to IEC 60038 Interference emission according to EN 55014 1 do mestic household applications Interference immunity according to EN 61000 4 4 in dustria...

Page 19: ...004 7 Electronically Protected Motor Component For motors with three speeds and corresponding quality mark rating plate Authorization FILE No E123518 UL 1004 3 Thermal device protected Motor Component...

Page 20: ...Machinery Directive 2006 42 EC Manufacturer ZIEHL ABEGG SE Heinz Ziehl Stra e 74653 K nzelsau Germany The following harmonized standards have been applied EN 60204 1 2018 Safety of machinery Electric...

Page 21: ...turer Start up of this incomplete machine is prohibited until it is ensured that the machine in which it has been installed complies with the provisions of the EC Machinery Directive K nzelsau 27 04 2...

Page 22: ...hinery Safety Regulations 2008 No 1597 The manufacturer is ZIEHL ABEGG SE Heinz Ziehl Stra e D 74653 K nzelsau The following harmonised standards have been used EN 60204 1 2018 Safety of machinery ele...

Page 23: ...It is prohibited to commission this incomplete machine until it has been secured that the machine into which it was incorporated complies with the stipulations of the Machinery Safety Regulations K nz...

Page 24: ...you are planning special applications please contact ZIEHL ABEGG SE Heinz Ziehl Stra e D 74653 K nzelsau Phone 07940 16 0 Fax 07940 16 300 info ziehl abegg de 8 5 Service address Please refer to the h...

Reviews: