Type FXDM32...50 (IP20)
Fastening at 4 points
GM00001A_M
15.12.2015
1
2
3
4
"
Drill 4 fastening points.
"
Screw in screws
“
1
”
-
“
4
”
up to a distance of approx. 5 mm and mount the device.
"
Tighten fastening point screws
“
1
”
-
“
4
”
.
4.4
Cable inlet
"
Remove the terminal compartment cover.
"
Depending on the housing model cut off necessary cable inlets respectively to the cable diameter.
Or alternative use cable inlet for cable glands. Metal sheet housings are supplied with stoppers.
Any cable ducts openings not used must be sealed!
"
Strip and insert the cables properly.
"
Attach cover for terminal compartment again carefully before start-up.
Housing with aluminum base plate
1
Cable inlet with step nozzles (factory installed)
1A
3 x max. 18 mm
1B
3 x max. 14 mm
1C
3 x max. 11 mm
1D
4 / 8 x max. 8 mm
2
attached cable inlet for cable glands
2A
17 / 21 mm
2B
12.5 / 17 mm
3
Fastening screws
Operating Instructions
Fcontrol
–
model series FXDM
Mounting
L-BAL-E072-GB 1642 Index 008
Part.-No.
13/105