Type
(Part-No.)
Rated cur-
rent
Output
{1}
[A]
Rated cur-
rent
(
I
fundamen-
tal compo-
nent @ 50
Hz)
Input
{2}
[A]
Rated tem-
perature
[
°
C]
max. line
fuse
{3}
[A]
Max. heat
dissipation
approx.
{2}
[W]
Noise ap-
prox.
{4}
[dB]
Weight
[kg]
Housing
protec-
tion
IP
FXDM40ME
(308175)
40
34.0 (31.5)
50
50
790
65.7
33.1
20
FXDM50AM
(308183)
50
47.5 (43.2)
50
63
910
65.7
32.8
54
FXDM50AM
(308227)
50
47.5 (43.2)
50
63
910
65.7
32.8
65
FXDM50M
(308184)
50
47.5 (43.2)
50
63
910
65.7
32.8
54
FXDM50AME
(308182)
50
47.5 (43.2)
50
63
910
65.7
36.7
20
FXDM50ME
(308181)
50
47.5 (43.2)
50
63
910
65.7
36.7
20
{1}
Rated current output
current indication rating plate @ rated voltage, @ rated temperature (cos
φ
0.8 at the output).
{2}
At rated voltage (cos
φ
0.8 at the output), values for different speci
fi
cations on request.
{3}
Max. line fuse on site (line protection fuse) according to EN 60204-1 Classi
fi
cation VDE0113 Part 1
{4}
Sound power level A-weighted by internal fan (- no indication)
Line voltage*
3 ~ 208...480 V (-15 up to +10 %), 50/60 Hz
Nominal voltage
400 V
Maximal output voltage
95 % of U
Line
Maximal output frequency
150 Hz (for FXDM22 max. 60 Hz permissible!)
Power factor
> 0.9
Switching frequency
16 kHz
Input resistance for sensor or signal
set for the rotational speed
for 0 - 10 V input: R
i
> 100 k
Ω
for 4 - 20 mA input: R
i
= 100
Ω
Voltage supply e.g. for sensors
+24 V
±
20 %, I
max
120 mA (for connection to an external AXG terminal minus approx.
50 mA)
Output (0 - 10 V)
I
max
10 mA (short-circuit-proof)
Digital inputs
“
D1
”
and
“
D2
”
Input resistance: R
i
approx. 4 k
Ω
Max. contact rating of the internal relay 2 A / 250 VAC
Max. permissible ambient temperature
for operation
55
°
C
Min. permissible ambient temperature
for operation
0
°
C (if mains voltage is not switched off up to -20
°
C)
To avoid condensation the device must be continuously energized due to the applica-
tion of heat, with interruptions such that cooling to the point of condensation does not
occur.
Permissible temperature range for
storage and transport
-30...+80
°
C (FXDM22: -30... +70
°
C)
Max. permissible installation height
0..4000 m amsl
above 1000 m amsl the rated current is to be reduced by 5 % / 1000 m
Permissible rel. humidity
85 % no condensation
Electromagnetic compatibility for the
standard voltage 230 / 400 V accord-
ing to DIN IEC 60038
Interference emission EN 61000-6-3 (domestic household applications)
Interference immunity EN 61000-6-2 (industrial applications)
Harmonics current
For devices < 4 A according EN 61000-3-2
For devices
≥
4 A and
≤
16A accorording EN 61000-3-2 (see Operating Instructions /
Electrical installation / harmonics current for devices
≥
4 and
≤
16 A)
Operating Instructions
Fcontrol
–
model series FXDM
Enclosure
L-BAL-E072-GB 1642 Index 008
Part.-No.
98/105