background image

1

General notes

Compliance with the following instructions is mandatory to ensure the functionality and safety of the 
product. If the following instructions given especially but not limited for general safety, transport, 
storage, mounting, operating conditions, start-up, maintenance, repair, cleaning and disposal / recy-
cling are not observed, the product may not operate safely and may cause a hazard to the life and 
limb of users and third parties.
Deviations from the following requirements may therefore lead both to the loss of the statutory material 
defect liability rights and to the liability of the buyer for the product that has become unsafe due to the 
deviation from the speci

cations. 

1.1

Validity

This document applies to PMblue centrifugal fans, whose permanent solenoid excited synchronous 
motors require a frequency inverter for electronic commutation.
The used motor size is recognisable from the type designation (see rating plate).
Type: ER__C-_KN.__.__
Type: GR__C-_KN.__.__

In the case of fans with the quality mark (see rating plate), please note the related speci

cations 

depending on the application location!

1.2

Structure of the assembly instructions 

Before installation and start-up, read this assembly instructions carefully to ensure correct use!
We emphasize that these assembly instructions apply to speci

c units only, and are in no way valid for 

the complete system!
Use these assembly instructions to work safely with and on the device. They contain safety instruc-
tions that must be complied with as well as information that is required for failure-free operation of the 
device.
Keep these assembly instructions together with the device. It must be ensured that all persons that 
are to work on the device can refer to the assembly instructions at any time.
Keep the assembly instructions for continued use. They must be passed-on to all successive owners, 
users and 

nal customers.

1.3

Target group

The assembly instructions address persons entrusted with planning, installation, commissioning and 
maintenance and servicing and who have the corresponding quali

cations and skills for their job.

1.4

Exclusion of liability

To allow for future developments, construction methods and technical data given are subject to 
alteration. We do not accept any liability for possible errors or omissions in the information contained 
in data, illustrations or drawings provided.
We accept no liability for damage caused by misuse, incorrect use, improper use or as a consequence 
of unauthorized repairs or modi

cations.

1.5

Copyright

These assembly instructions contain copyright protected information. The assembly instructions may 
be neither completely nor partially photocopied, reproduced, translated or put on data medium without 
previous explicit consent from ZIEHL-ABEGG SE. Infringements are liable for damages. All rights 
reserved, including those that arise through patent issue or registration on a utility model. 

Assembly instructions 

PMblue

General notes

L-BAL-F073-GB 2033 Index 003

Part.-No. 00703805-GB

4/22

Summary of Contents for PMblue

Page 1: ...PMblue Fan with permanent solenoid excited synchronous motor PM motor and highest ef ciency Assembly instructions Keep for reference L BAL F073 GB 2033 Index 003 Part No 00703805 GB english...

Page 2: ...8 3 3 Note on the ErP directive 8 3 4 Transport storage 9 3 5 Disposal recycling 9 4 Mounting 10 4 1 General notes 10 4 2 Erecting the equipment Design ER 11 4 3 Optimal installation distances accordi...

Page 3: ...9 6 Service information 22 Assembly instructions PMblue L BAL F073 GB 2033 Index 003 Part No 00703805 GB 3 22...

Page 4: ...ructions to work safely with and on the device They contain safety instruc tions that must be complied with as well as information that is required for failure free operation of the device Keep these...

Page 5: ...rts e g guard grille as a resting surface or climbing aid Fans are not designed for walking on even with an additive diffusor attachment retro t kit Do not climb onto fans without suitable aids Unauth...

Page 6: ...or instructed and apprentices are only permitted to work on the device under the supervision of an experienced person This also applies to personnel undergoing general training Comply with the legal m...

Page 7: ...he assembly instructions and or operating instructions are always readily available at the location where the device is being used are complete and are in legible condition These persons are regularly...

Page 8: ...motor being used This can be found on the parameter storage medium ZAstick which accompanies this motor By transferring the motor and fan parameters to the frequency inverter from ZIEHL ABEGG optimum...

Page 9: ...port the fan s either in the original packaging or in the case of larger fans on the dedicated transportation xtures axial fans holes drilled in support arms wall ring plates and motor block centrifug...

Page 10: ...stom designs must suit the prevailing conditions Take into account easy access for cleaning and maintaining the fan Before installing the fan make sure the safety distances are maintained compliant wi...

Page 11: ...e bearings if the fan remains stopped in a moist environment Avoid corrosion by suitable protective measures Roo ng is required Corrosion is possible at the cutting edges on sendzimir galvanised parts...

Page 12: ...e motor 4 6 Cable inlet Attention Only use lines which can guarantee a permanent seal around the cable glands pressure resistant dimensionally stable round centred jacket e g by means of gusset lling...

Page 13: ...enoid excited synchronous motors may never be operated directly on mains A compatible frequency inverter is always required for electronic commutation Direct connection to the mains can lead to destru...

Page 14: ...e following 1 Installation and electrical connection have been properly completed 2 Has any leftover installation material and other foreign material been removed from the fan area 3 Sicherheitseinric...

Page 15: ...pes brushes When indicated clear foreign bodies dirt from the fan Active temperature management effective Motor or electronics overheated Check for free air passages remove foreign bodies if necessary...

Page 16: ...ing Any impellers corroded in this way must be replaced immediately Deposits on the motor particularly on the cooling vanes and in recesses on the rotor can lead to reduced cooling performance and the...

Page 17: ...le minimal and maximal am bient temperature for operation 20 40 C rating plate Please see the technical documentation of the product for the minimum and maximum ambient temperature valid for the respe...

Page 18: ...ingebauten Temperaturf hlern with internal thermistors 3 1 J1 E1 1 E1 2 TB TP 0 20 mA 0 10 V 10 V PWM 15 28 V PWM 5 6 Temperaturf hler Thermistors TP Thermostatschalter Thermostats TB 7 Service parame...

Page 19: ...f machinery electrical equipment of machines Part 1 General requirements EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN ISO 13857 2008 Safety...

Page 20: ...ations of the EC Machinery Directive K nzelsau 03 09 2018 location date of issue ZIEHL ABEGG SE Dr W Angelis Technical Director Air Movement Division name function ZIEHL ABEGG SE Dr D Kappel Deputy He...

Page 21: ...ct points 11 cooling 16 D damping elements 11 E ErP directive 8 I Imbalance 15 L lifting beam 10 R rating plate 16 S safety distances 10 sound power levels 14 strength class 11 Structure borne noise 1...

Page 22: ...l abegg de http www ziehl abegg com 9 6 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical support for control systems v...

Reviews: