3.4

Transport, storage

Attention!

Observe the weight speci

cations (see rating plate) and the permissible carrying loads of the means 

of transport.

Wear safety clothing / shoes and cut-resistant safety gloves when handling.

Do not transport the fan by the connecting cable!

Avoid shocks and impacts to the device during the transport.

Avoid extreme humidity, heat or exposure to cold (see technical data). 

Watch out for possible damage to the packaging or fan.

Fix pallets during transport.

Do not stack pallets.

Only handle with suitable hoisting gear.

Position the lifting beam transversely to the motor axis. Pay attention to adequate width of the lifting 
beam.

Never stand underneath the suspended fan because defective transport equipment could cause 
death.

Store the fan / motor in the original packaging in a dry area protected from the weather and protect 
it from dirt and weather until 

nal installation.

Avoid prolonged storage; we recommend a maximum of one year (consult the manufacturer before 
starting if stored for longer).

Inspect the bearing for proper operation prior to installation.

Recommendation: Turn the impeller evenly by hand to avoid jamming and damaging the 
bearing.

Transport the fan(s) either in the original packaging or, in the case of larger fans, on the dedicated 
transportation 

xtures.

axial fans: holes drilled in support arms, wall ring plates and motor block

centrifugal fans depending on type: holes drilled in the housing 

ange, motor block, fastening 

brackets and support plates, 

Radial impellers, fans with scroll RG.., RD.. or built-in fans type ER../GR.., WR.. are generally 
delivered on europallets, and can be transported using lift trucks.

Design RG.. / RD.. / ER.. / GR../ WR../HR..

 : Fan unit may only be lifted and transported when 

using a suitable hoisting device (load spreader). Ensure suf

cient cable or chain length. 

Design FV.. / DN..

 : The fan must be fastened to 4 points during transport so the 

anges do not 

warp.

Design WR: maximum permissible number for lifting fan units mounted on top of one another

Size

External dimensions [mm]

Permissible number

1

607 x 607

5

2

760 x 760

4

3

912 x 912

3

Attention!

Lifting several fan units next to one another is prohibited!

3.5

Disposal / recycling

Disposal must be carried out professionally and in an environmentally friendly way in accordance with 
the respective national legal stipulations.

"

Separate the materials by type and in an environmentally friendly way.

"

If necessary, commission a specialist company with the waste disposal.

Assembly instructions 

PMblue

Product overview

L-BAL-F073-GB 2033 Index 003

Part.-No. 00703805-GB

9/22

Summary of Contents for PMblue

Page 1: ...PMblue Fan with permanent solenoid excited synchronous motor PM motor and highest ef ciency Assembly instructions Keep for reference L BAL F073 GB 2033 Index 003 Part No 00703805 GB english...

Page 2: ...8 3 3 Note on the ErP directive 8 3 4 Transport storage 9 3 5 Disposal recycling 9 4 Mounting 10 4 1 General notes 10 4 2 Erecting the equipment Design ER 11 4 3 Optimal installation distances accordi...

Page 3: ...9 6 Service information 22 Assembly instructions PMblue L BAL F073 GB 2033 Index 003 Part No 00703805 GB 3 22...

Page 4: ...ructions to work safely with and on the device They contain safety instruc tions that must be complied with as well as information that is required for failure free operation of the device Keep these...

Page 5: ...rts e g guard grille as a resting surface or climbing aid Fans are not designed for walking on even with an additive diffusor attachment retro t kit Do not climb onto fans without suitable aids Unauth...

Page 6: ...or instructed and apprentices are only permitted to work on the device under the supervision of an experienced person This also applies to personnel undergoing general training Comply with the legal m...

Page 7: ...he assembly instructions and or operating instructions are always readily available at the location where the device is being used are complete and are in legible condition These persons are regularly...

Page 8: ...motor being used This can be found on the parameter storage medium ZAstick which accompanies this motor By transferring the motor and fan parameters to the frequency inverter from ZIEHL ABEGG optimum...

Page 9: ...port the fan s either in the original packaging or in the case of larger fans on the dedicated transportation xtures axial fans holes drilled in support arms wall ring plates and motor block centrifug...

Page 10: ...stom designs must suit the prevailing conditions Take into account easy access for cleaning and maintaining the fan Before installing the fan make sure the safety distances are maintained compliant wi...

Page 11: ...e bearings if the fan remains stopped in a moist environment Avoid corrosion by suitable protective measures Roo ng is required Corrosion is possible at the cutting edges on sendzimir galvanised parts...

Page 12: ...e motor 4 6 Cable inlet Attention Only use lines which can guarantee a permanent seal around the cable glands pressure resistant dimensionally stable round centred jacket e g by means of gusset lling...

Page 13: ...enoid excited synchronous motors may never be operated directly on mains A compatible frequency inverter is always required for electronic commutation Direct connection to the mains can lead to destru...

Page 14: ...e following 1 Installation and electrical connection have been properly completed 2 Has any leftover installation material and other foreign material been removed from the fan area 3 Sicherheitseinric...

Page 15: ...pes brushes When indicated clear foreign bodies dirt from the fan Active temperature management effective Motor or electronics overheated Check for free air passages remove foreign bodies if necessary...

Page 16: ...ing Any impellers corroded in this way must be replaced immediately Deposits on the motor particularly on the cooling vanes and in recesses on the rotor can lead to reduced cooling performance and the...

Page 17: ...le minimal and maximal am bient temperature for operation 20 40 C rating plate Please see the technical documentation of the product for the minimum and maximum ambient temperature valid for the respe...

Page 18: ...ingebauten Temperaturf hlern with internal thermistors 3 1 J1 E1 1 E1 2 TB TP 0 20 mA 0 10 V 10 V PWM 15 28 V PWM 5 6 Temperaturf hler Thermistors TP Thermostatschalter Thermostats TB 7 Service parame...

Page 19: ...f machinery electrical equipment of machines Part 1 General requirements EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction EN ISO 13857 2008 Safety...