background image

1 General notes

Compliance with the following instructions is mandatory to ensure the functionality and 
safety of the product. If the following instructions given especially but not limited for 
general safety, transport, storage, mounting, operating conditions, start-up, mainte-
nance, repair, cleaning and disposal / recycling are not observed, the product may not 
operate safely and may cause a hazard to the life and limb of users and third parties.
Deviations from the following requirements may therefore lead both to the loss of the 
statutory material defect liability rights and to the liability of the buyer for the product that 
has become unsafe due to the deviation from the speci

cations. 

1.1 Structure of the operating instructions

Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to speci

c units only, and are in 

no way valid for the complete system!
Use these operating instructions to work safely with and on the device. They contain 
safety instructions that must be complied with as well as information that is required for 
failure-free operation of the device.
Keep these operating instructions together with the device. It must be ensured that all 
persons that are to work on the device can refer to the operating instructions at any time.

1.2 Exclusion of liability

To allow for future developments, construction methods and technical data given are 
subject to alteration. We do not accept any liability for possible errors or omissions in the 
information contained in data, illustrations or drawings provided.
We accept no liability for damage caused by misuse, incorrect use, improper use or as a 
consequence of unauthorized repairs or modi

cations.

2 Safety instructions

Installation, electrical connection and commissioning to be carried out by trained 
service personnel only. The speci

cations of the manufacturer or supplier, and 

instructions relating to the equipment, should be rigidly adhered to. Failure to comply 
with these conditions will invalidate the guarantee on our controllers and accessories!

The 5 electrical safety rules must be observed!

It is strictly forbidden for work to be carried out on any components while they are 
connected to live voltage. The open equipment is protected to IP00. It is possible to 
come into direct contact with dangerous voltages!

The safe isolation from the supply must be checked using a 

two-pole

 voltage 

detector.   

Cover neighbouring electrical equipment during installation work.

During operation, the device must be closed or installed in a control cabinet. Fuses 
may only be replaced by new ones and must not be repaired or bypassed. The data 
for the maximum line fuse are to be considered absolutely (see Technical data). Use 
only fuses speci

ed in schematic diagrams.

Never clean electrical equipment with water or similar liquids.

Operating Instructions 

S-ET... / S-DT...

General notes

L-BAL-E058-GB 1931 Index 002

Part.-No. 

3/12

Summary of Contents for S-ET Series

Page 1: ...S ET S DT Switching units for 1 and 3 motors Operating Instructions Keep for reference L BAL E058 GB 1931 Index 002 Part No english D GB F NL PL www ziehl abegg com...

Page 2: ...3 1 Function 5 3 2 Maintenance 5 3 3 Transport 5 3 4 Storage 5 3 5 Disposal recycling 6 4 Installation 6 4 1 General notes 6 4 2 Mains connection 7 4 3 Motor connection 7 4 4 Operating indicator conta...

Page 3: ...ure developments construction methods and technical data given are subject to alteration We do not accept any liability for possible errors or omissions in the information contained in data illustrati...

Page 4: ...ing of the motor fan the appropriate instructions in the drive documentation must be observed Attention Even after switching off dangerous temperatures can still occur in and on the device Attention A...

Page 5: ...OFF or speed change over of one or more motors via the integrated switch The maximum total current of all motors should not exceed the rated current of the device Integrated operating indicator lamp...

Page 6: ...e the appropriate mounting devices for proper installation of the unit Do not mount equipment on vibrating base Do not allow drilling chips screws and other foreign bodies to reach the device interior...

Page 7: ...cted connect thermostatic switches to the TK TK terminals in series Special function Automatic restart when motor has cooled down Automatic restart when motor has cooled down if the both terminals J J...

Page 8: ...age at terminal 12 if fan is not running also in switch position 0 18 04 2008 v_kla_steu_1dra_feder_2dra VSD M AC 230 V M 1K M AC 230 V M 2K M AC 24 V 230 V M 3K L L N L L N 11 14 N 12 5 Enclosure 5 1...

Page 9: ...le ambient temperature 40 C Housing plastic housing ABS Housing protection IP54 Weight approx 1 1 kg 5 2 Connection diagram S ET1KT N L1 PE Netz Line 1 230 V 50 60 Hz 12 11 14 N L L RT RT TK TK 1 5 0...

Page 10: ...tern with internal thermostats 2 TB L2 L3 S DT2S K T N L1 PE Netz Line 3 400 V 50 60 Hz 12 11 14 N L L RT RT TK TK 1 5 0 1 Aus Ein Off On 3 1 Wenn Funktion nicht ben tigt wird Klemmen br cken If funct...

Page 11: ...DT32KT N L1 PE Netz Line 3 400 V 50 60 Hz 12 11 14 N L L RT RT TK TK 1 5 0 1 Aus Ein Off On 3 1 Wenn Funktion nicht ben tigt wird Klemmen br cken If function is not needed terminals must be bridged 1...

Page 12: ...49 0 7940 16 504 info ziehl abegg de http www ziehl abegg de 5 5 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical supp...

Reviews: