Information

Important additional information and advice for user.

2.2 Requirements placed on the personnel / due diligence

Persons entrusted with the planning, installation, commissioning and maintenance and 
servicing in connection with the frequency inverter must have the corresponding qual-
i

cations and skills for these jobs.

In addition, they must be knowledgeable about the safety regulations, EU/EC directives, 
rules for the prevention of accidents and the corresponding national as well as regional 
and in-house regulations. Personnel to be trained or instructed and apprentices are only 
permitted to work on the device under the supervision of an experienced person. This 
also applies to personnel undergoing general training. Comply with the legal minimum 
age. 

3 Product overview

3.1 Function

The switching units (depending on type S-ET... or S-DT...) are designed for switching 
manual ON-/OFF or speed change-over of one or more motors via the integrated 
switch. The maximum total current of all motors should not exceed the rated current 
of the device.

Integrated operating indicator lamp (goes out in the case of motor fault) and control 
fuse.

Remote control (ON/OFF) via potential-free contact (terminals RT - RT). If remote 
OFF lamp for power not OFF!

3.2 Maintenance

The device must be checked for soiling and, if necessary, cleaned in periodic intervals.

3.3 Transport

The device is packed ex factory to suit the transport method previously agreed.

Always use the original packaging materials when transporting the device.

Avoid shocks and impacts to the device during the transport.

During manual handling the human lifting and carrying restrictions must be observed 
and adhered to.

3.4 Storage

The device must be stored in its original packaging in a dry and weather-proof room.

Avoid exposure to extreme heat and cold.

Avoid over-long storage periods (we recommend a maximum of one year).

Operating Instructions 

S-ET... / S-DT...

Product overview

L-BAL-E058-GB 1931 Index 002

Part.-No. 

5/12

Summary of Contents for S-ET Series

Page 1: ...S ET S DT Switching units for 1 and 3 motors Operating Instructions Keep for reference L BAL E058 GB 1931 Index 002 Part No english D GB F NL PL www ziehl abegg com...

Page 2: ...3 1 Function 5 3 2 Maintenance 5 3 3 Transport 5 3 4 Storage 5 3 5 Disposal recycling 6 4 Installation 6 4 1 General notes 6 4 2 Mains connection 7 4 3 Motor connection 7 4 4 Operating indicator conta...

Page 3: ...ure developments construction methods and technical data given are subject to alteration We do not accept any liability for possible errors or omissions in the information contained in data illustrati...

Page 4: ...ing of the motor fan the appropriate instructions in the drive documentation must be observed Attention Even after switching off dangerous temperatures can still occur in and on the device Attention A...

Page 5: ...OFF or speed change over of one or more motors via the integrated switch The maximum total current of all motors should not exceed the rated current of the device Integrated operating indicator lamp...

Page 6: ...e the appropriate mounting devices for proper installation of the unit Do not mount equipment on vibrating base Do not allow drilling chips screws and other foreign bodies to reach the device interior...

Page 7: ...cted connect thermostatic switches to the TK TK terminals in series Special function Automatic restart when motor has cooled down Automatic restart when motor has cooled down if the both terminals J J...

Page 8: ...age at terminal 12 if fan is not running also in switch position 0 18 04 2008 v_kla_steu_1dra_feder_2dra VSD M AC 230 V M 1K M AC 230 V M 2K M AC 24 V 230 V M 3K L L N L L N 11 14 N 12 5 Enclosure 5 1...

Page 9: ...le ambient temperature 40 C Housing plastic housing ABS Housing protection IP54 Weight approx 1 1 kg 5 2 Connection diagram S ET1KT N L1 PE Netz Line 1 230 V 50 60 Hz 12 11 14 N L L RT RT TK TK 1 5 0...

Page 10: ...tern with internal thermostats 2 TB L2 L3 S DT2S K T N L1 PE Netz Line 3 400 V 50 60 Hz 12 11 14 N L L RT RT TK TK 1 5 0 1 Aus Ein Off On 3 1 Wenn Funktion nicht ben tigt wird Klemmen br cken If funct...

Page 11: ...DT32KT N L1 PE Netz Line 3 400 V 50 60 Hz 12 11 14 N L L RT RT TK TK 1 5 0 1 Aus Ein Off On 3 1 Wenn Funktion nicht ben tigt wird Klemmen br cken If function is not needed terminals must be bridged 1...

Page 12: ...49 0 7940 16 504 info ziehl abegg de http www ziehl abegg de 5 5 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical supp...