5.13
Digital outputs (X-IN-OUT)
The connection terminal X-IN-OUT is equipped with 2 digital outputs as zero potential relay contacts
with normally open function.
5.13.1
Function of the outputs
Output
Function
Explanation
RDY
"ready" message
Contact is closed if no error is present in the ZArec4C.
Contact opens in case of error or parameter input.
When the RDY output is open, the EN input may not be acti-
vated.
/ERR
"error" message
Contact is closed if no error is present in the ZArec4C.
Contact opens when errors occur which require the system to be
switched off.
It must be ensured that the system is locked when switching off
the /ERR output. Errors must be
fi
xed by quali
fi
ed personnel.
5.13.2
Lead
•
Shielded cables must be used. The shieldings must be connected to the shield connection of the X-
IN-OUT terminal.
•
It is recommended to use the pre-assembled connection cable LS-ZArec4C-xx-HX-xx-ZA3/4.
5.13.3
Technical data
Short-circuit-proof
no*
Min. switching capacity
5 mA / 12 VDC
Max. switching capacity
2 A / 250 VAC
Cable cross section
max. 1,5 mm
²
Caution
High interrupting voltages
Destruction of relay contacts
"
Inductances must be provided with an external protective circuit (free-running diode, RC-member).
5.13.4
Connection
For connecting digital outputs see Chapter "Digital inputs (X-IN-OUT) / connection".
5.14
Input X-EN_MC (only in the case of ZArec4C 026/039)
If the bridge at the input X-EN_MC is removed, the activation of the internal mains relay is interrupted.
Original operating instructions
ZArec4C
Electrical installation
R-TBA14_03-GB 1817 Index 007
Part.-No. 00163436-GB