Wiring diagram Motor
5.4
Absolute encoder connection
Caution!
Never touch the connection contacts on the position absolute encoder or on the cable! The electronics can be
destroyed by static electricity.
"
The absolute encoder must be connected to the frequency inverter.
"
The absolute encoder contains components that may be damaged by electrostatic discharge. The
body of the person touching them must
fi
rst be discharged, for example, by touching a conductive,
earthed object, (e.g. bright metal parts of a control panel), immediately beforehand.
"
A shielded cable must be used for the encoder connection. It is recommended to use a ZIEHL-
ABEGG SE cable which guarantees a suf
fi
cient shield connection.
"
The absolute encoder must not be detached mechanically in order not to lose the factory settings. If
the absolute encoder has been detached, the new encoder-offset has to be determined with the
frequency inverter. Please see the inverter operation instructions for this procedure.
Contacts SV120 round connector at absolute encoder ECN1313 (ZIEHL-ABEGG SE standard)
Pin
Signal
Description
A
DATA
Data line for communication with the absolute encoder
B
DATA /
Data line inverse
C
5 V Sensor Up
Sensor cable for encoder voltage (5 V positive)
D
5 V Up
Cont5 V voltage supply (positive)
E
0 V Un
Ground voltage supply absolute encoder (negative)
F
B+ (sine)
Analog track B (sine)
GCLOCK /
Clock signal invers
H
CLOCK
Clock signal for serial transfer
J
0 V Sensor Un
Sensor cable for encoder voltage (negative)
K
A+ (cosine)
Analog track A (cosine)
L
A- (cosine inverse)
Analog track A invers (cosine invers)
M
B- inverse (sine inverse)
Analog track B invers (sine invers)
Electrical installation
$7%$B*%
Part.-No. 01008166-GB (
EU-BD 845
)
9/68
2ULJLQDORSHUDWLQJLQVWUXFWLRQV
ZAtop
–
model series SM160.30B/40B