5.4
Absolute encoder
Attention!
"
Never touch the connection contacts on the position absolute encoder or on the cable! The electronics can be
destroyed by static electricity.
"
You must discharge your own body before touching. This can be done, for example, by touching a conductive,
earthed object (for example bare metal switch cabinet parts) immediately before.
"
Operation of the elevator machine without an absolute encoder is not permissible.
5.4.1
Cable length
•
Maximum line length: 25 m
•
Connection and extension cable: Available as an option
•
Connection and extension cable version: Shielded twisted pair cable
Absolute encoder
ECN1313
EnDat
ECN1313
SSI
AE-
S64-
BISSC-
05-ZA
ERN1387
AE-
S64-
SinCos-
07-AE
Adapter ca-
bles
Connection
Jumper
M16 x 0.75
(SV120)
x
x
x
Jumper
M23 x 1
x
x
x
Jumper
D-SUB 15-pin
x
x
x
Wire-end
sleeves
x
Cable length
0.22 m
0.245 m
x
x
x
x
x
x
0.35 m
x
0.56 m
x
x
1.8 m
x
5.0 m
x
7.0 m
x
Connecting cable frequency inverter
(optional)
x
x
x
Extension cable (optional)
x
x
x
x
x
x
Table 5-4-1
Translation of the original operating instructions
ZAtop
–
model series SM200.40E/SM200.45E
Electrical installation
A-TBA21_01-GB 2021/30 Index 003 Part.-No. 01013507-GB (EU-BD 1112)
17/64