5.5.5
Connection
•
The terminal box for the brake may be removed from the elevator machine and mounted on site for
a better attainability.
•
The brake is only allowed to be supplied with power when fastened to the motor and after having
connected the protective conductor of the motor at the control and the motor side.
•
The brakes must be protected with varistors against overvoltage from switching operations. The
varistor must lie directly on the coil or its connections.
5.5.6
Connection diagram
Brake wiring diagram with inductive proximity switch
Figure 5-5-6-01
(1) Brake release monitoring
(2) Brake
(3) Minimum strength 2 mA DC
(4) Operating voltage range 10 - 30 V DC
(5) Shown with currentless brake
5.6
Forced ventilation
The forced ventilation is optional and can be added afterwards.
5.6.1
Technical data
Voltage
220 - 240
[V]
Frequency
50 / 60
[Hz]
Power
48 / 45
[W]
Current
0.24 / 0.23
[A]
Table 5-6-1-1
5.6.2
Connection diagram
Figure 5-6-1-2-01
1 Thermal contact
Original operating instructions
ZAtop
–
model series SM315.100A
Electrical installation
A-TBA22_02-GB 2022/50 Index 002 Part.-No. 01013486-GB (EU-BD 1075)
23/76