5.18.1.2
Assignment connection terminal X400 (ZAdyn4C MRL AI)
X400
1
5
6
7
13
14
K7.1
6T3
5L3
K7
8
21
22
22
21
K141
K140
21
22
22
21
K7.1
K7
1
2
Connecting diagram contactor monitoring ZAdyn4C MRL AI
1
Monitoring brake contactors
K7
Brake contactor AC-side
K7.1
Brake contactor DC-side
2
Monitoring the standstill
K140
Contactor for manual brake release brake A
K141
Contactor for manual brake release brake B
K7
Brake contactor AC-side
K7.1
Brake contactor DC-side
5.18.1.3
Assignment connection terminal X-K (ZAdyn4C MRL Bx)
X-K1
1
2
3
4
1
2
21
22
13
14
K3
K4
21
22
K4
K3
Connecting diagram contactor monitoring ZAdyn4C MRL Bx -
integrated brake contactor
K3
Brake contactor AC-side
K4
Brake contactor DC-side
5.18.1.4
Fault and speed monitoring frequency inverter (only ZAdyn4C MRL AI)
X300
18
17
X-OUT
2 (O14)
1 (O11)
Connecting diagram fault monitoring
X-OUT
Output "Fault"
X400
8
9
X-OUT
8 (O44)
7 (O41)
Connecting diagram speed monitoring
X-OUT
Output "V < V_G1"
Original operating instructions
ZAdyn4C MRL
Electrical installation
R-TBA14_01-GB 1845
Part.-No. 00163419-GB
30/44