Dot in the info menu/page 03
"
Leave the info menu with the key.
"
Set the parameter
Start-up/HY_Auto
to "Off".
Overcurrent messages may appear in some cases during tuning journeys. The corresponding journey
is then interrupted by the ZAdyn4CA HY. In this situation, the ZAdyn4CA HY tries to correct the motor
characteristic for the coming journey. In such a case continue the tuning process as usual after the
fault message of the ZAdyn4CA HY with the journey to the bottom
fl
oor. As soon as 5 journeys in a
row have been interrupted with overcurrent, the tuning process should be interrupted. The version of
the ZAdyn4CA HY must be checked.
6.5
Optimization of parameter values to improve travel characteristics
If travel comfort is not satisfactory after performing the tuning function, it can still be improved by the
manual adjustment of parameters.
Problem
Adjustment
Cabin overshoots the target
fl
oor in the case of a light
load at the end of travel or there is very hard interrup-
tion of the travel in relation to
fl
ush position.
Reduce the parameter
Start-up/HY_OFFS
in approx.
3% steps.
Cabin comes too early to a standstill in the case of a
light load.
Increase the parameter
Start-up/HY_OFFS
in ap-
prox. 3% steps.
Cabin only overshoots the target
fl
oor at the end of
travel in the case of a large load.
Reduce the parameter
Start-up/HY_LA_V
in steps of
1
Cabin only comes too early to a standstill in the case
of a large load.
Increase the parameter
Start-up/HY_LA_V
in steps
of 1
When adjusting by means of the control system the
cabin fails to move.
Increase the parameter
Start-up/HY_NACH
in steps
of 500
Hard travel start with subsequent clear reduction in
acceleration or oscillation in the acceleration.
Increase the parameter
Start-up/HY_DMP
in 5%
steps.
Important: Depending on the system characteristics,
this parameter can also increase rather than weaken-
ing the effect.
6.6
Travelling in the inspection run
In most systems, the cabin can already be moved with the default standard values in the ZAdyn4CA
HY. After activating the inspection button, it can take up to 4 seconds for the cabin to start to move.
However, if no movement occurs:
•
Check whether the pump runs forward (see the chapter "Pump drive wiring")
•
Check the motor data
•
Increase the parameter
Start-up/HY_O_A
by approx. 500 and start a new travel attempt. Repeat
this until a movement occurs.
•
If the speed driven is too high, reduce the parameter
Start-up/HY_O_A
by approx. 200
6.7
Reset ZAdyn4CA HY to delivery state
Set the parameter
Statistics/Reset=99
. The ZAdyn4CA HY restarts presetting itself with the factory-
set standard parameters. All previously set values are reset! This process lasts for approx. 1 minute.
Quick Start Guide
ZAdyn4CA HY
Start-up
R-TBA16_01-GB 1845 Index 003
Part.-No. 00163456-GB
17/28
Summary of Contents for ZAdyn4CA 018 HY
Page 25: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 25 28 ...
Page 26: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 26 28 ...
Page 27: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 27 28 ...