background image

9.2

Type designation 

   

ZAdyn

 

4

 

xx

 

0xx

- HY

 

  

 

                       

 

Series

 

 

                       

 

 

                       

 

   

 

 

                       

 

4th generation

 

 

                       

 

 

                       

 

   

 

 

                       

 

Structure

 

 

                       

 

CA

 

 

                       

 

Complete unit for asynchronous motors

 

 

                       

 

including power choke, 

lter, for operation without contactors 

 

 

                       

 

  

 

                       

 

CS

 

 

                       

 

Complete unit for synchronous motors

 

 

                       

 

including power choke, 

lter, integrated short-circuit, for operation 

without contactors 

 

 

                       

   

 

 

                       

 

Rated current   

 

 

                       

 

 

 

                       

 

011

11 A

 

 

                       

 

013

13 A

 

 

                       

 

017

17 A

 

 

                       

 

018 (HY)

18 A

 

 

                       

 

023

23 A

 

 

                       

 

025 (HY)

25 A

 

 

                       

 

032

 32 A

 

 

                       

 

040

 40 A

 

 

                       

 

050

 50 A

 

 

                       

 

062

62 A

 

 

                       

 

063 (HY)

 63 A

 

 

                       

074

 74 A

 

 

                       

 

080 (HY)

 80 A

 

 

                       

 

105 (HY)

 105 A

 

 

                       

 

  

 

                       

 

Additional designation

 

 

                       

 

MRL AI

 

 

                       

 

with add-on module and integrated brake resistor

 

 

                       

 

  

 

                       

 

MRL BI

 

 

                       

 

without add-on module, with integrated brake resistor

 

 

                       

 

  

 

                       

 

MRL BE

 

 

                       

 

without add-on module, with external brake resistor

 

 

                       

 

  

 

                       

 

HY

 

 

                       

 

for hydraulic elevators

 

 

                       

Quick Start Guide 

ZAdyn4CA HY

Enclosure

R-TBA16_01-GB 1845 Index 003

Part.-No. 00163456-GB

22/28

Summary of Contents for ZAdyn4CA 018 HY

Page 1: ...B 1845 Index 003 Part No 00163456 GB ZA dyn4CA HY Frequency inverter for hydraulic elevators Quick Start Guide Store for future use Additional information to the operating instructions of the ZAdyn4C R TBA12_01 GB ...

Page 2: ...tion 10 5 2 2 Type of cable 10 5 2 3 Cable length 10 5 2 4 Connection 10 5 2 5 Pump drive wiring 11 5 3 Motor temperature monitoring X MT 11 5 4 STO interface X STO 12 5 5 DCP interface X DCP 12 5 6 Circuit suggestion ZAdyn4CA HY 13 6 Start up 14 6 1 Prerequisites for commissioning 14 6 2 Switching on the ZAdyn4CA HY 14 6 3 Parameterisation of the ZAdyn4CA HY 14 6 4 Tuning function 15 6 5 Optimiza...

Page 3: ...9 4 Index 24 Quick Start Guide ZAdyn4CA HY R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 3 28 ...

Page 4: ...orated into the next version ZIEHL ABEGG SE is not liable for damage due to misuse incorrect use improper use or as a consequence of unauthorized repairs or modifications 2 Safety instructions The Safety informations described in chapter 2 of theoperating instructions R TBA12_01 has to be followed 3 Product overview 3 1 Application The ZAdyn4CA HY is a field orientated Frequency inverter for speed c...

Page 5: ...floor distances must be kept with Speed m s min floor distance m 0 3 0 94 0 4 1 26 0 5 1 73 0 6 2 03 0 7 2 39 0 8 2 83 1 0 3 67 Geschwindigkeit m s 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 min Stockwerksabstand m 0 5 1 5 2 5 3 5 1 2 3 4 Diagram of speed minimum floor distance Quick Start Guide ZAdyn4CA HY Product overview R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 5 28 ...

Page 6: ... the acceleration curve must be set to maximum acceleration Set times which help start up delay to the minimum In the following chapters there is a description of the settings to be made in the case of valve blocks tested by ZIEHL ABEGG 4 2 1 Bucher LRV 1 Bucher LRV 1 No modicications on the valve block are necessary Keep the existing settings Quick Start Guide ZAdyn4CA HY Mechanical installation ...

Page 7: ...ck EV100 Blain version 2 a Valve 3 b Valve 2 c Valve 5 d Valve 1 e Valve 4 Make the settings according to the following table Valve Setting Valve 1 closed Valve 2 open Valve 3 open Valve 4 open Valve 5 open Quick Start Guide ZAdyn4CA HY Mechanical installation R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 7 28 ...

Page 8: ...ssure or circulating pressure valve A Screw in the upward pressure or circulating pressure valve A until it is flush with the lock nut Quick Start Guide ZAdyn4CA HY Mechanical installation R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 8 28 ...

Page 9: ...ine cross section must be specified dependent on the motor s rated current and the ambient conditions e g temperature wiring method in accordance with DIN VDE 0100 5 1 3 Mains fuse The size of the mains fuse must reflect the cable cross section used and the ambient conditions Use the following maximum fuse sizes depending on the frame size of the ZAdyn4CA HY ZAdyn frame size Max fuse for operating c...

Page 10: ...le lines Rated voltage U0 U 450 750 VAC 5 2 3 Cable length The maximum line length is 25 m With a motor power line 25 m compliance with DIN EN 12015 electromagnetic compatibility spurious emission and DIN EN 12016 electromagnetic compatibility interference immunity can no longer be guaranteed 5 2 4 Connection Danger Always switch off the mains voltage when connecting the motor line The STO functio...

Page 11: ...nformation The X MT connection terminal is a standard part of the ZAdyn4CA HY Information The detection of over temperature of the motor doesn t cause a drive interruption The current drive will be completed If an over temperature of the motor will be detected at stop there is no further drive possible The temperature monitoring is carried out according to IEC 61800 5 1 2003 02 switching point at ...

Page 12: ...The ZAdyn4CA HY is connected to the elevator control system via DCP4 The ZAdyn4CA HY can only be actuated via the DCP interface with the DCP_04 protocol Use a shielded cable for the connection The shielding must be grounded on the inverter side Configure the connection between the ZAdyn4CA HY and the control system without additional terminal points The maximum line length is 50 m X DCP DA DB 0VD D...

Page 13: ...5 6 Circuit suggestion ZAdyn4CA HY ZD4C01K9 Quick Start Guide ZAdyn4CA HY Electrical installation R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 13 28 ...

Page 14: ...splay appears ZIEHL ABEGGSE ZAdyn4CA 025 HY SN 12345678 123 Phone 49 794016308 6 3 Parameterisation of the ZAdyn4CA HY The motor data must be stored in the ZAdyn4CA HY To do so enter the following parameters as per motor name plate Information Should there be two rating plates available on the system on the motor and on the unit then always use the rating plate on the unit Start up n 2700 rpm 2700...

Page 15: ...le to use the ZAdyn4CA HY for normal travels the tuning function must be performed beforehand This happens almost completely automatically by the ZAdyn4CA HY itself Only several calls have to be made by the control system During these tuning travels the ZAdyn4CA HY gradually adjusts the necessary parameters itself Tuning function for load free operation Check the turning direction of the pump see ...

Page 16: ...ly calculate an average from the different target values and programme it in the parameter Start up HY_O_A or Start up HY_OFFS Afterwards the tuning process for load free operation is ended and you can continue as normal Leave the info menu with the key Set the parameter Start up HY_Auto to Off Tuning function for load operation Load the cabin with nominal load Set the parameter Start up HY_Auto t...

Page 17: ...a large load Reduce the parameter Start up HY_LA_V in steps of 1 Cabin only comes too early to a standstill in the case of a large load Increase the parameter Start up HY_LA_V in steps of 1 When adjusting by means of the control system the cabin fails to move Increase the parameter Start up HY_NACH in steps of 500 Hard travel start with subsequent clear reduction in acceleration or oscillation in ...

Page 18: ... pump at which the cabin no longer moves 0 10000 0 HY_LA_l No load current in the case of empty cabin 0 1 100 0 A 28 0 A HY_LA_V Speed gain in the case of fully loaded cabin 1 500 25 HY_NACH Adjustment value 100 8000 2000 FIL_V_D Filter time constant V_DCP Determination of speed via DCP control 2 2048 16 INFO menu DCP Ident 14 Info xx 0101 010106 en Load 211 0mm s Page 14 DCP Ident Information abo...

Page 19: ...hich can only occur in the case of the ZAdyn4CA HY Error 5xx Error no Error text Error cause M S 595 HY No movement Fault ZAdyn4CA HY could not detect any cabin movement Remedy Check whether cabin is blocked Check whether the command for an inspection run has been given when performing the tuning function Quick Start Guide ZAdyn4CA HY Error diagnosis R TBA16_01 GB 1845 Index 003 Part No 00163456 G...

Page 20: ... during standstill W 25 26 27 27 Power loss standby 1 W 18 18 19 19 Power loss standby 2 W 14 15 16 17 Switching frequency kHz 4 16 Motor frequency Hz max 200 Max terminal cross section line motor mm2 16 Min line diameter for strain relief Motor mm 11 11 11 14 Ambient conditions The user must ensure that the specified ambient conditions are observed Protection rating as per DIN EN 60529 IP20 Ambien...

Page 21: ...issipation in Standby 2 4CA W 19 21 23 23 Switching frequency kHz 4 16 Motor frequency Hz max 200 Terminal range mains mm2 0 5 35 rigid 1 0 25 fine wire with wire end ferrule Terminal range motor mm2 0 5 35 rigid 1 0 25 fine wire with wire end ferrule Min line diameter for strain relief Motor mm 18 18 20 25 Ambient conditions The user must ensure that the specified ambient conditions are ob served Pr...

Page 22: ...t contactors Rated current 011 11 A 013 13 A 017 17 A 018 HY 18 A 023 23 A 025 HY 25 A 032 32 A 040 40 A 050 50 A 062 62 A 063 HY 63 A 074 74 A 080 HY 80 A 105 HY 105 A Additional designation MRL AI with add on module and integrated brake resistor MRL BI without add on module with integrated brake resistor MRL BE without add on module with external brake resistor HY for hydraulic elevators Quick S...

Page 23: ...yn4CA 025 HY 352241 ZAdyn4CA 032 HY 352242 ZAdyn4CA 040 HY 352243 ZAdyn4CA 050 HY 352244 ZAdyn4CA 063 HY 352245 ZAdyn4CA 080 HY 352246 ZAdyn4CA 105 HY 352247 Quick Start Guide ZAdyn4CA HY Enclosure R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 23 28 ...

Page 24: ...9 Exclusion of liability 4 F fault diagnosis 19 I informations 4 M Mains connection 9 Mechanical Installation 6 Motor connection 10 Motor temperature monitoring 11 S start up 14 T Technical data 2 20 Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 24 28 ...

Page 25: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 25 28 ...

Page 26: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 26 28 ...

Page 27: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 27 28 ...

Page 28: ...al modifications Customer Service phone 49 7940 16 308 fax 49 7940 16 249 drives service ziehl abegg com Headquarters ZIEHL ABEGG SE Heinz Ziehl Strasse D 74653 Kuenzelsau Germany phone 49 0 7940 16 0 fax 49 0 7940 16 249 drives ziehl abegg de www ziehl abegg com ...

Reviews: