background image

ZETA Dry Contact Sensor

11

Power on

Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.

power socket

Summary of Contents for ZETA OCZ1ZT92

Page 1: ...ZETA Dry Contact Sensor 1 ZETA Dry Contact Sensor...

Page 2: ...ZiFiSense Disclaimer This specification is preliminary and is subject to change at any time without prior notice ZiFiSense assumes no responsibility for any errors contained herein ZiFiSense is not re...

Page 3: ...escription 4 2 Applications 4 3 Appearance 4 4 Features 4 5 Specifications 5 6 Packing List 5 7 Installation 6 7 1 Screw 6 7 2 Adhesive 3M 8 7 3 Cable Ties 9 8 Use of Device 12 8 1 Steps for usage 12...

Page 4: ...t remains in standby mode with ultra low power consumption when there is no such signal triggered 2 Applications Building property and industry where dry contact sinals are need to be detected 3 Appea...

Page 5: ...trical Features Power supply Battery 2 ER14505 Battery capacity 2 2700 mAh Stand by current 10 A Working current 70 mA Physical Features Size 66 55 36 mm Enclosure material ABS Waterproof level IP30 A...

Page 6: ...f tapping screw M3 20 2 device 2 4 expanded plastic pipe 2 3 Percussion drill 4 drill bit hammer 1 4 slotted screwdriver cross screwdriver 1 7 1 2 Installation instructions Open the device case Use a...

Page 7: ...to secure the device in the mounting position Power on Insert the power plug into the upper power socket install two 14505 batteries remove the insulation sheet for the existing battery and close the...

Page 8: ...ife 2 7 2 2 Installation instructions Installation position Select a flat mounting position and clean it up Open the device case Use a slotted screwdriver to open the top cover from the bottom edge Po...

Page 9: ...ive film of the 3M adhesive and install the device to the specified position 7 3 Cable Ties 7 3 1 Auxiliary material No Materials Quantity 1 Metal cable ties 5 300mm 2 2 Slotted screwdriver utility kn...

Page 10: ...ZETA Dry Contact Sensor 10 Fixation Pass the 2 cable ties through the device and secure to the installation rod opening Installation position...

Page 11: ...A Dry Contact Sensor 11 Power on Insert the power plug into the upper power socket install two 14505 batteries remove the insulation sheet for the existing battery and close the upper cover power sock...

Page 12: ...ery report heartbeat period can set or query the dry contact status reporting cycle Range 1 65535 min default 2 60min Set Query acquisition period The period of which the device collects sensor inform...

Page 13: ...ch can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna I...

Page 14: ...ZETA Dry Contact Sensor 13...

Reviews: