background image

WARNING!

•  To be installed and/or used in accordance with appropriate 

electrical codes and regulations.

•  If you are unsure about any of these instructions, consult a 

qualified electrician.

•  Unplug unit when servicing connected lamps.

•  Save this instruction sheet. It contains important technical 

data along with testing and troubleshooting information 
which will be useful after installation is complete.

Specifications and Supported Leads

Power:  

Supported Loads:

 

120 VAC 60Hz 

300 Watts

 
 

Step 1: 

Attach the plug from the lamp to be controlled into 

the receptacle of the Lamp Module.

Step 2:

Attach Lamp Module to wall receptacle. Verify that the 
receptacle is powered. If the receptacle is powered by a wall 
switch, the wall switch must be kept ON at all times for the 
module to operate properly.

Step 3:

To join the Lamp Module to a certified HA controller be sure that 
the HA controller is open for joining. If the Lamp Module has not 
been joined to a network then press and hold the Lamp Module 
button. The Lamp Module will continuously blink as it attempts 
to join an open HA network.
Upon a successful joining of the Lamp Module to a ZigBee HA 
network, the status LED will stop blinking.
If the Lamp Module will not join a Zigbee HA network then:

•  Make sure the Lamp Module is powered up.

•  Ensure the Lamp Module is within RF range of a routing 

device.

•  Make sure the target Zigbee network is open for joining.

Step 4

Once the Lamp Module is joined to the Zigbee HA network, use 
the certified HA controller to configure the Lamp Module.

Step 5:

If it becomes necessary to remove the Lamp Module from 
a Zigbee HA network then you must factory default the 
Lamp Module. To factory default the Lamp Module:

1. Remove the Lamp Module from the wall receptacle
2. Press and hold the Lamp Module’s button
3. Reinstall the Lamp Module into the wall receptacle while 

holding the button

4. After 2 seconds the status LED will turn ON
5. Once the LED is ON let go of the button

6. The Lamp Module will now be reset to factory defaults and 

begin scanning for a ZigBee HA network to join.

Troubleshooting

If the Lamp Module is not working properly, proceed with the 
following steps:

1. Make sure the device is being supplied with a 120V, 60 Hz 

AC source.

2. Check the lamp that is being controlled. Is it turned on?
3. Make sure the controlled load does not exceed 300 Watts.
4. If the load works locally with the Lamp Module button but 

does not respond to network commands, then repeat 
installation steps starting with Step 1.