background image

3

2.1 To get started, you will need:

A ZigBee Gateway

.

A mobile app.

2.2 Installation

The LED Lighting Driver must be installed by qualified electrical personnel, 
keep the wiring diagram below for future reference.

 

  

 

 

 

 

 

 

 

 

 

   

       

 

C- 

V+ 

W- 

ACN   

ACL   

CCT Panel 

 

C- 

V+ 

ACN   

ACL   

SC Panel 

SLC612 LED driver

SLC612 LED driver

SMART LED DRIVER
INPUT : 100-240VAC   0.40A   50/60Hz

OUTPUT : 24-38VDC Max 950mA

Max current can be set by app

SEC wire prep

0.5 -1.5mm²

 

8 - 9mm

PRI wire prep.

0.75mm²

Class 2 Power Supply

L

W -
C -
V +

GND 

0 -10V +

0 - 10V  

Input

Output

AC In

SMART LED DRIVER
INPUT : 100-240VAC   0.40A   50/60Hz

OUTPUT : 24-38VDC Max 950mA

Max current can be set by app

SEC wire prep

0.5 -1.5mm²

 

8 - 9mm

PRI wire prep.

0.75mm²

Class 2 Power Supply

L

W -
C -
V +

GND 

0 -10V +

0 - 10V  

Input

Output

AC In

Wiring Diagram

Summary of Contents for 612

Page 1: ...C 0 40A 50 60Hz OUTPUT 24 38VDCMax950mA Maxcurrentcanbesetbyapp SECwireprep 0 5 1 5mm 8 9mm PRI wire prep 0 75mm Class2PowerSupply N L W C V GND 0 10V 0 10V Input Output AC In SLC612 LED Lighting Driver Dimming CCT Quick Start Guide ...

Page 2: ... L W C V GND 0 10V 0 10V Input Output AC In Get started 2 Warning The LED Lighting Driver must be installed and serviced only by qualified electrical personnel Do not touch the terminals of the device during testing Turn off all power supplying this equipment before installing Make sure that the power supply is off before connecting or disconnecting it to the auxiliary device Always use a properly ...

Page 3: ...612 LED driver SLC612 LED driver SMARTLEDDRIVER INPUT 100 240VAC 0 40A 50 60Hz OUTPUT 24 38VDCMax950mA Maxcurrentcanbesetbyapp SECwireprep 0 5 1 5mm 8 9mm PRI wire prep 0 75mm Class2PowerSupply N L W C V GND 0 10V 0 10V Input Output AC In SMARTLEDDRIVER INPUT 100 240VAC 0 40A 50 60Hz OUTPUT 24 38VDCMax950mA Maxcurrentcanbesetbyapp SECwireprep 0 5 1 5mm 8 9mm PRI wire prep 0 75mm Class2PowerSupply ...

Page 4: ...tomatically and the brightness of the LED panel light will drop to 50 when successfully joined 4 Now you can control the LED Lighting Driver remotely from your mobile app Note If the LED Lighting Driver fails to join the gateway s network within a minute simply reset the LED Lighting Driver and retry Reset Turn ON and turn OFF Repeat this action three times using a physically connected power suppl...

Page 5: ...cs Operating frequency 2 4GHz Range outdoor indoor 100m 30m ZigBee Profile ZigBee Lighting Link Profile Power Input 100 240 VAC 50 60 Hz Output Current 950mA MAX Output Voltage 24 38 V Operation temperature 40ºC 60 ºC Operation humidity 85 No condensation Dimensions 118 x 74 x 32 L mm Weight 185g ...

Page 6: ...d all the safety notices below before using the LED Lighting Driver 4 Avoid high humidity or extreme temperatures Avoid long exposure to direct sunlight or strong ultraviolet light Do not drop or expose the unit to intense vibration Do not disassemble or try to repair the unit yourself Do not expose the unit or its accessories to flammable liquids gases or other explosives ...

Reviews: