4.7 MONITOR SET

The function of monitor set is real time monitor of over current, over heat and freezing, on Home interface, short 
press          MONITOR SET to enter into monitor set interface as follows: 

For configuration method and modification, please refer to Automatic Mode 
(Energy Save Mode) Schedule:

After Mode: set the mode after the drying mode ends, can be configured through the proprietary attribute 
ModeAfterDry (0x1007) of Thermostat Cluster (0x0201).

Duration: set how long the dry mode lasts, can be configured through the proprietary attribute DryTime 
(0x1006) of Thermostat Cluster (0x0201), the configurable range is 5-100 minutes.  

For example, in order to quickly dry the water on the floor of the bathroom, the device can be set to quickly heat 
in a short time to dry the floor. Enter the configuration interface as follows:

4.6 Dry Mode Schedule

Remain: shows the remaining time of the drying mode

To enter into the setting interface and setting method, please refer to the 1.4 
Auto Mode (Energy Save Mode) Schedule.

Start and end mean away time.

D means date, M means month, Y means year (2019-2099).

2.If away mode has already been activated, the values of end time for away mode are set as 0, the device will 
always execute current set temperature with no time limitation. The device will consider the mode as anti-
freeze mode, the recommended temperature setting is 4-10

℃, 

and

 

factory

 

default

 

setting

 

is

 

6

℃.

4.5 Away Mode Schedule

User can set time to leave home and time to go home according to the requirements of themselves, and set how 
the device will control the temperature during this period.
1.If away mode has already been activated, the end time for away mode is valid, the device will execute Away 
Mode Temperature Schedule before the end time.

Hysterersis (0.5°C by default)

To prevent the undulation of sensor temperature when the sensor temperature is approaching the set

 

temperature, which will cause that the controller may keep switching on/off the relay. Here hysterersis enables 
the controller to control the relay only when the sensor temperature is a little bit lower than the set temperature, 
this value can be set. 
For instance, when hysterersis is set as 0.5 degree, then only when current sensor temperature is 0.5 degree 
lower than the set temperature, will the controller heat, if the sensor temperature >= set temperature, the 
controller will not heat.
This value can also be configured through the proprietary attribute Hysterersis (0x100A) of Thermostat Cluster 
(0x0201).
Note: This hysterersis only valid when the control type is single sensor, please refer to the part Control Type.

reported to the associated devices, meanwhile the buzzer or vibrator will beep 3 times every 10 seconds. The 
over heat alarm function can be disabled, which can be set directly through the device. Or can be configured 
through the attribute AlarmAirTempOverValue (0x2001) of Thermostat Cluster (0x0201), when this value is set 
as 0, this function is disabled.
Over heat alarm interface is as follow:

Note: to cancel over current alarm or over heat alarm, just press and hold 
button  

     

 for over 3 seconds or reset power of the device. After cancel 

manually, the relay will show heating forbidden icon 

     

  within 120 

seconds, but other operations are allowed.

Max Current (16A by default)

If current is over the set value, the relay will be forced to off by the device, and the state will be reported to the 
gateway. The over current alarm function can be disabled, which can be set directly through the device. Or can 
be configured through the ACAlarmsMask and ACCurrentOverload of Electrical Measurement (0X0B04), for 
details please refer to the configuration value . 

RoomTemp alarm (

by default)

45°C 

If room temperature is over the set value, the relay will be forced to off by the device, and over heat alarm will be 

Short press button

      

to select the item would like to modify, then short press 

move up and move down buttons                to modify value of selected item, then 
short press button

  

   to save and quit, short pressing button  

    

only quits 

without saving.

F

Window Open Detect (disabled by default)

Once the device is powered on and stable, referring to the room temperature sensor, if the temperature 
decreases to the threshold of this setting, the window open mark will be enabled, the relay will be forced to turn 
off to save energy, then the icon        will appear.

After window open mark is enabled, if the temperature increases to the threshold of this setting in 3 minutes, 
the window open mark will be disabled.
Once the window open mark is enabled, it will be disabled after 10 minutes, and the device will keep current 
working mode.

This value can also be configured through the proprietary attribute WindowOpenCheck (0x1009) of Thermostat 
Cluster (0x0201), 0 means this function is disabled.
Note: this function will work better when the device is installed beside the window or door.

7:30,24

  ~ 12:00,20

℃  

18:00,16

 ~  22:30,18

  

Saturday~Sunday
7:30,24

  ~  12:00,20

  

18:00,18

 ~  22:30,18

Short press button  

    

 to select the item would like to modify, then short 

press move up and move down buttons    

     

 to modify value of selected 

item, then short press button 

     

 to save and quit, short pressing button   

only quits without saving.

4.9 OTHER SET

Select  

     

OTHER SET on Home Interface to enter into OTHER SET interface as follow:

F

Short press button 

    

  to select the item would like to modify, then short 

press move up and move down buttons     

     

to modify value of selected 

item, then short press button  

    

 to save and quit, short pressing button 

   

  

only quits without saving.

F

4.8 TIME/DATE SET

Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:

The device Time Cluster is client, if the bound device supports local time of Time Cluster, the device will 

acquire local time from the bound device spontaneously under 3 situations: acquire after this device is added 

to a network, acquire when the device already added to a network and power is reset, acquire every 24 hours .

Summary of Contents for ROB-200-040-0

Page 1: ...EMC RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1...

Page 2: ...1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes will be displayed alternatively for 3 s...

Page 3: ...x2001 of Thermostat Cluster 0x0201 when this value is set as 0 this function is disabled Over heat alarm interface is as follow Note to cancel over current alarm or over heat alarm just press and hold...

Page 4: ...ribute TemperatureDisplay 0x1008 of Thermostat Cluster 0x0201 Operate Brightness Mid Level by default The OLED display brightness when operate the device Adding to a Zigbee Network Operate your Zigbee...

Page 5: ...server Scenes Allows storing one or more scenes per group where each scene consists of a pre set on off state value You may either store the current values as a scene or provide scene settings when ad...

Page 6: ...format allows 0 1 C Default value 0 0x0011 int16S reportable OccupiedCoolingSetpoint This system is not invalid 0x0012 int16S reportable OccupiedHeatingSetpoint Range is 0 4000 the maximum resolution...

Page 7: ...16U read only reportable RMSVoltage Single phase valid voltage unit is V 0x0508 int16U reportable read only RMSCurrent Single phase valid current unit is A 0x050B int16S reportable read only ActivePow...

Page 8: ...executed when away mode is selected Check whether away mode time is set as 0 or within valid time range 4 Over heat alarm when power on the device Possible reason the set sensor type is not correct o...

Reviews: