Floor Sensor (NTC 10K by default)

If external sensor is broken, the user can buy NTC sensor by themselves, the available sensor types are as 
follows:
NTC 100K/25 (3m,NTC,R25=100KΩ±1%@25

, B25/50=3950K±1%)

NTC 50K/25 (3m,NTC,R25=50KΩ±1%@25

, B25/50=3950K±1%)

NTC 15K/25 (3m,NTC,R25=15KΩ±1%@25

, B25/50=3950K±1%)

NTC 10K/25 (3m,NTC,R25=10KΩ±1%@25

℃, 

B25/50=3950K±1%)

NTC 12K/25 (3m,NTC,R25=12KΩ±1%@25

℃, 

B25/50=3950K±1%)

This sensor type can also be configured through the proprietary attribute FloorSensorType (0x1002) of 
Thermostat Cluster (0x0201).

Key vibration level (OFF by default)

Set the level of vibration sensor under the buttons or buzzer level.
OFF: vibration or buzzer off
Low Level, High Level: low vibration or buzzer level, high vibration or buzzer level
This level can also be configured through the proprietary attribute ButtonVibrationLevel (0x1001) of 
Thermostat Cluster (0x0201).

Control type (Room sensor by default)

Control type means which temperature sensor the device refers to when it adjust temperature.

Room sensor:

 adjust temperature refers to room temperature (factory default type)

Floor sensor: 

adjust temperature refers to floor temperature

Room+Floor sensor:

 adjust temperature refers to both room temperature and floor temperature. Turn on heat 

valve under other circumstances. This mode is to prevent the device from continuous heating that caused by 
malfunction of either sensor. When the floor sensor temperature is >= the set temperature minus 1 or when the 
room sensor is >= the set temperature, either of the conditions is achieved, the controller will stop heat, 
otherwise the controller will heat. 
This control type can also be configured through the proprietary attribute ControlType (0x1003) of Thermostat 
Cluster (0x0201).

Temp compensation (0 by default)

The displayed temperature may has big tolerance caused by the sensor or other factors, so it is necessary to do 
temp compensation to room sensor and floor sensor.
Compensation range is -5 ~ +5 , stepping is 0.5 .

This value can also be configured through the attribute LocalTemperatureCalibration (0x0010) of Thermostat 
Cluster (0x0201), and through the proprietary attribute FloorSensorCalibration (0x1005) of Thermostat Cluster 
(0x0201).

RePower status(last status by default)

Device state after reset power of the device.
If set as “last status”, device will go to the status before power failure after power on again.
If set as “default”, device will go to default mode after power on again.
This status can also be configured through the proprietary attribute PowerUpStatus (0x1004) of Thermostat 
Cluster (0x0201).

Display Temp type (Home Temp by default)

This parameter defines which sensor temperature will be displayed on Home page.
Floor Temp: floor temperature (external sensor).
Home Temp: indoor air temperature.
This status can also be configured through the proprietary attribute TemperatureDisplay (0x1008) of 
Thermostat Cluster (0x0201).

Operate Brightness (Mid Level by default)

The OLED display brightness when operate the device.

Adding to a Zigbee Network

Operate your Zigbee gateway to add device, select “Add”, then short press button 

    

 , the device will search 

network and try to join, “Status” will show “Inclusion...”. If there is no response from a gateway, or adding failed, 
“Status” will show “Fail”. If added successfully, “Status” will show “Inclusion OK” and device ID.

Removing from a Zigbee Network 

Operate your Zigbee gateway to remove device, Select “Remove”, then short press button

    

  , the device will 

send out removing request, “Status” will show “Exclusion...”. If there is no response from a gateway, or 
removing failed, “Status” will show “Fail”. If removed successfully, “Status” will show “Exclusion OK” and device 
ID will be showed as 0.
The device will be removed from the network and all parameters will be restored to factory default setting, all 
bindings will be cleared.

F

F

Select   

    

Network Set on Home Interface to enter into Zigbee network management interface as follow:

4.10 Zigbee Configuration Introduction

Internal

 

Over

 

Heat

 

Protection

To

 

ensure

 

the

 

safety

 

of

 

the

 

device

if

 

the

 

internal

 

temperature

 

of

 

the

 

device

 (

not

 

displayed

 

on

 

the

 

interface

)

 

is

 

over

 

a

 

certain

 

value

 

during

 

heating

 

process

the

 

device

 

will

 

execute

 

a

 

short

 

temporary

 

action

 

to

 

turn

 

off

 

the

 

relay

and

 

the

 

icon

      

will

 

appear

 

on

 

the

 

interface

 , 

after

 

the

 

temperature

 

decreases

 

to

 

a

 

certain

 

value

the

 

device

 

will

 

recover

 

to

 

work.

Factory Reset (Reset)

Factory resetting will remove the device from Zigbee network and all parameters will be restored to factory 
default setting, all bindings will be cleared.
Select “Reset”, then short press button

    

  , the device will start reset, “Status” will show “Reset...”. If 

exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”.

F

Configure Device Operation Mode through Zigbee

Since Zigbee does not have away mode, the attribute Occupancy (occupied or unoccupied) of Thermostat

 

(0x0201)

 

and

 

attribute

 

Occupancy

 

of

 

received OccupancySensing (0x0406) are

 

required

 

to

 

judge

 

whether

 

it

 

is

 

away

 

mode.

1)

 

if

 

the

 

device

 

receives

 

other

 

devices’

 

or

 

the

 

gateway’s

 

report: the

 

Bit

 

0

 

of

 

the

 

value

 

of

 

attribute

 

Occupancy

 

(0x0000)

 

of OccupancySensing Cluster

 

(0x0406)

 

is

 

1, which

 

means

 

occupied, then the 

operation mode of the thermostat, the attribute SystemMode(0x001c)=0x04(heat)

 

of Thermostat

 

(0x0201), 

High Level, Mid Level, Low Level.
This brightness can also be configured through the proprietary attribute OperateDisplayLcdBrightness 
(0x1000) of Thermostat Cluster (0x0201).

Display Auto Off (60S by factory setting)

By factory setting, once the device goes to standby interface, if there is no operation within 1 minute, the 
display will go off automatically.

Child Lock

On the Home Interface, press and hold both         and         buttons for over 10S, the Child Lock can be enabled 
or disabled, when the Child Lock is enabled, the icon        will appear at the upper right corner, otherwise the 
icon will not appear.

Summary of Contents for ROB-200-040-0

Page 1: ...EMC RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1...

Page 2: ...1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes will be displayed alternatively for 3 s...

Page 3: ...x2001 of Thermostat Cluster 0x0201 when this value is set as 0 this function is disabled Over heat alarm interface is as follow Note to cancel over current alarm or over heat alarm just press and hold...

Page 4: ...ribute TemperatureDisplay 0x1008 of Thermostat Cluster 0x0201 Operate Brightness Mid Level by default The OLED display brightness when operate the device Adding to a Zigbee Network Operate your Zigbee...

Page 5: ...server Scenes Allows storing one or more scenes per group where each scene consists of a pre set on off state value You may either store the current values as a scene or provide scene settings when ad...

Page 6: ...format allows 0 1 C Default value 0 0x0011 int16S reportable OccupiedCoolingSetpoint This system is not invalid 0x0012 int16S reportable OccupiedHeatingSetpoint Range is 0 4000 the maximum resolution...

Page 7: ...16U read only reportable RMSVoltage Single phase valid voltage unit is V 0x0508 int16U reportable read only RMSCurrent Single phase valid current unit is A 0x050B int16S reportable read only ActivePow...

Page 8: ...executed when away mode is selected Check whether away mode time is set as 0 or within valid time range 4 Over heat alarm when power on the device Possible reason the set sensor type is not correct o...

Reviews: