Fig. 25. Replacing o-ring seal in filling head adapter
Warranty terms – technical inspections schedule
The prerequisite for maintaining the machine's warranty during its validity period is, among others,
to respect the schedule of technical inspections of machinery performed by Zigler Polska service
personnel. During the base warranty period of 24 months, according to the general terms, at least
2 technical inspections are required to be carried out with intervals specified in following schedule:
Warranty inspection
Period
1-st
Not later than 6 months after
start-up/commissioning of the
machine
2-nd
Not later than 18 months after
start-up/commissioning of the
machine
O-ring seal
17 mm
22 mm
Adapter
17 mm
Service key
9003.46.001.2
Adapter nut
Gasket 9003.34.650.0
Spring 9003.34.005.1/SG2
Sealing sleeve 9003.34.651.1
Summary of Contents for Z-2323