SR981S/SR982S operation manual of solar pump station
Page 9 of 85
4. Attention Items for solar station installation
Note:
In order to avoid jam the digital flow meter and in result to displays no flow on solar
station, the filter must be installed on the return and flow pipeline of solar station.
All devices connected to the controller must conform to the technical specifications of
the controller, assembly, installation and maintenance work may only be performed by
properly qualified and authorized personnel with a generally recognized qualification.
The solar station must be installed indoors, prior to installation, remove sealing caps
from solar station.
According to the manual of expansion vessel to install and adjust it, the pipeline for
connecting pump station and expansion vessel should be not insulated.
Safety valve: Risk of scalding from hot steam with discharge from the safety valve due
to heating and excess pressure in the hydraulic pipes. Using a copper pipe to drain the
discharged liquid from the safety valve to the barrel and disposed it in an eco-friendly
Filter