SR981S/SR982S operation manual of solar pump station
Page 68 of 85
condition is met, controller will heat the second tank, but this heating time is controlled by
parameter tRUN, when the tRUN heating time is gone, controller stops to heat the
second tank, and collector is heated by solar within so named tSTP time, if within this tSTP
time, the switch-on condition of the first priority tank is still not met, then controller starts to
heat second tank again for tRUN time, if the switch-on condition of the first priority tank is
met, then the first priority tank is heated, intermission heating function is ceased
automatically.
Setup steps:
To select submenu tRU
N, “tRUN 15” displays on the
screen.
► Press “SET” button, parameter “15” displays and blinks,
factory set is “15 seconds”
► Press “ ” button to adjust time, adjustable
range: 01~ 30 minutes, factory set is “15 minutes”
►Press “ESC” button to exit the menu or wait for 20 seconds to exit, parameters are
saved automatically.
8.5.11.2 tSTP Intermission heating run-off time
Setup steps:
To select submenu tSTP, “tSTP 02” displays on the
screen.
► Press “SET” button, parameter “02” displays and blinks
► Press “ ” button to adjust time, adjustable
range: 01~ 30 minutes
, factory set is “02 minutes”
►Press “ESC” button to exit the menu or wait for 20 seconds to exit, parameters are
saved automatically.
Functions
Default value
Adjustable range
PRIO priority tank
01
00 ~ 02, Su1, Su2
tSTP interval heating run-off
time
2 minutes
01 ~ 30 minutes
tRUN interval heating run-on
time
15 minutes
01 ~ 30 minutes