Z8018x
Family MPU User Manual
42
UM005004-0918
To avoid address conflicts with external I/O, the Z8X180 internal I/O
addresses can be relocated on 64-byte boundaries within the bottom 256
bytes of the 64KB I/O address space.
I/O Control Register (ICR)
ICR allows relocating of the internal I/O addresses. ICR also controls
enabling/disabling of the IOSTOP mode.
I/O Control Register (ICR: 3FH)
Bit
7
6
5
4
3
2
1
0
Bit/Field
IOA7
IOA6
IOSTP
—
—
—
—
—
R/W
R/W
R/W
R/W
Reset
0
0
0
R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W
Value
Description
7
–
6
IOA7:6
R/W
IOA7 and IOA6 relocate internal I/O as depicted in
Figure . The high-order 8 bits of 16-bit internal I/O
addresses are always 0. IOA7 and IOA6 are cleared to 0
during RESET.
5
IOSTP
R/W
IOSTOP mode is enabled when IOSTP is set to 1.
Normal. I/O operation resumes when IOSTP is reset to 0.