ZIMM Screw Jack
6 Installation
2015-01
Version 1.2
19
6.4
Connecting the electrical components
WARNING
Electric shock!
Electric shock can lead to death or serious injuries.
Allow only skilled electricians to work on the electrics.
Comply with the basic rules:
– Deenergise the system.
– Secure it against switching on again.
– Ensure all phases are electrically dead.
– Earth and short-circuit the system.
– Cover any adjacent parts that are still live.
6.4.1
Motor
The motor (if supplied) must be installed.
1. Open the motor terminal box. The connection assignment is shown
within the motor terminal box.
2. Connect the motor in accordance with the circuit diagram.
6.4.2
Limit switch
Fig. 12:
Fitting the plug connector on the limit switch
1. Remove the protection element (1) from the limit switch.
2. Remove the protection element (2) from the plug connector.
3. Insert the plug connector (3) into the limit switch.
4. Turn the screw (4) 90° clockwise.
Connecting the limit
switch