ZIMM Actuator
6 Installation
20
Version 0.6
2023
6.4
Connecting the electrical components
WARNING
Electric shock!
Electric shock can lead to death or serious injuries.
Allow only skilled electricians to work on the electrics.
Comply with the basic rules:
– Deenergise the system.
– Secure it against switching on again.
– Ensure all phases are electrically dead.
– Earth and short-circuit the system.
– Cover any adjacent parts that are still live.
6.4.1
Motor
The motor (if supplied) must be installed.
1. Open the motor terminal box. The connection assignment is shown
within the motor terminal box.
2. Connect the motor in accordance with the circuit diagram.
6.5
Trial running
The system must be installed and aligned.
The spindle must be greased (for more information see section
CAUTION
Lateral forces due to incorrect alignment!
Damage to the gearbox and spindle.
1. If the alignment is defective: Correcting the alignment, see
2. Repeat the trial run.
High forces are generated!
Damage to the ZIMM Actuator.
Make sure that the limit switches or end positions are not exceeded.
Make sure that attachments do not collide with other parts.
Summary of Contents for ZA-25
Page 33: ......