12
10.2.2 Setting the pressure range
You can switch the pressure between two pressure ranges.
Pressure range [bar]
Function
Supply voltage [V DC]
4.5–5.5
I4 input open
0
5.5–6.5
Wiring
+ 24
10.2.3 Installing the wiring
NOTICE
Non-compliance may result in material damage.
►
Secure the electrical supply lines to be mounted with a suitable strain relief to prevent the uncontrolled
removal of the pins.
►
Connect the product according to its
assignment diagram.
1
1
Electrical connection
I4
I5
P2
I1
I2
P3
I1
I3
I2
I4 I5
Controller
P1
C1
I6 I7 I8
C2
C3
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
INSTALLATION AND OPERATING INSTRUCTIONS:
AEPN1100-00-A
DDOC01693 / a
EN / 2023-03-20
Summary of Contents for AEPN1100-00-A
Page 2: ......