44
11.4.3 Integrating the library
►
In the
Options
menu, click
Global Libraries
.
►
Click
Open Library
.
Ö
The
Libraries
window opens.
►
Click the
Zimmer_Group_Indradrive
global library.
►
Click the
Templates
folder.
►
Go to the
Templates
folder and copy the data types
UDT_AXIS_IN
,
UDT_AXIS_OUT
and the variable
st_IndraDriveUnit_Parameter_z
.
►
In
Project navigation
in the
Devices
tab, click
PLC_2
.
►
Click the
PLC Data Types
folder.
►
Paste the copied data types and variable to the
PLC Data Types
folder.
►
Go to the
Templates
folder and copy the function blocks
FB_
GEH8660_z
,
FB_Zimmer_Indradrive_DCP_z
and
FC_InPosReal_z
.
►
Click the
Program Modules
folder.
►
Paste the copied function blocks to the
Program Modules
folder.
Ö
The function blocks are required for activation.
►
Using drag & drop with the mouse, move the function block file
FB_
IndraDrive_Errors_z
from the
Errorhandling English
or
Errorhandling
German
folder to the PLC project depending on the desired language
to be used.