11.4.6 Using the function block
►
On the function block added, switch multiple inputs and outputs.
►
Connect the input structure
st_AxisData_In
found in the function
block to the corresponding variable
st_AxisData_GEH8660_In
.
►
Connect the output structure
st_AxisData_Out
found in the function
block to the corresponding variable
st_AxisData_GEH8660_Out
.
Ö
The function block reads out the individual statuses and positions of
the drive control unit and processes them.
Ö
The drive control unit can be configured by connecting outputs.
►
Transfer the required data so that the drive control unit can activate
the motor.
INFORMATION
In the example project, these standard values are stored in flag ranges and thus can be connected flexibly.
►
These values can be found in the "Input values" section.
►
Transfer the settings to the PLC control system.
►
Complete the steps necessary for Siemens:
• Save/transmit
• Load into the device