11.5.15 st_Parameter (TIA)
The positions and basic settings are compiled in the variable
st_IndraDriveUnit_Parameter_z
. These can be changed during
runtime.
In the example, the parameters are partially defined in
Main (OB1) Network 1
.
11.6 Input values
An entry of 0 -100% is possible for speed and acceleration. Entering 0 corresponds to the minimum value and 100 to the
maximum value.
An entry of 0 - 300% for the torque is possible like in the drive control unit.
GEH8660 (gear ratio: 375:49 | feed constant 3.1415 mm)
Variable
Value range
Input value
Corresponding value
i_Velocity
0 - 2503
50
1251,5 mm/min
i_Acceleration
0 - 21400
50
10700 mm/s
2
i_Torque
0 - 300
200
200 %