Cooling system
The cooling system must meet the requirements for the intended use.
Component parts of the cooling system for the product include:
•
Connecting lines (use a line with a large cross-section)
•
Coolant (observe pH value)
• Cooling unit
•
Attachment structure/motor spindle
The cooling system must be implemented as a closed system!
Ö
Do not use an open cooling basin.
Ö
Use under exclusion of oxygen.
Ö
The coolant must be available to the cooling circuit in the defined quantity and temperature.
pH value of the coolant
The coolant medium must meet the requirements for the intended use. Unsuitable coolant can lead to thermally insulating
deposits on parts that transfer heat. Zimmer GmbH accepts no liability for any resulting malfunctions or damage.
Zimmer GmbH recommends the use of “Cool-Core Ready” from Motorex, “SK3301.960” from Rittal or a comparable
coolant. All trials and test runs were carried out with one of the coolants specified above.
Incorrect pH value of the coolant
The coolant must be changed if the pH value is not between 6.5 and 8.5. Otherwise, damage to or impairment of the
cooling circuit may result. The coolant filtration must lie within the prescribed range.
Use of the coolant
The local approvals, guidelines and laws apply for the use of coolant.
Material specifications of the product
INFORMATION:
The owner/operator must check whether its coolant is suitable for the material composition of the product.
Zimmer GmbH accepts no liability for any damage that may result from use of unsuitable coolants.
Component
Material
Housing
3.2315 (AlMgSi1)
Seals
FKM