background image

User manual and manufacturer s specifications

Your roof protects the building, furnishings and assets. In 
order for you to be able to enjoy a fully functional roof in the 
long-term, it has to be installed professionally and maintained 
at regular intervals during use and, where necessary, re-
paired. In order to do this it is important to ensure that works 
carried out on a roof can be carried out safely. The client and 
(perhaps later on) the owner is also under obligation here and 
is responsible for ensuring compliance with all specifications 
relating to occupational safety on a roof.

ZinCo Fallnet

®

 ASG, in conjunction with a green roof serving 

as ballast, is a collective edge protection system for temporary 
maintenance works in accordance with EN 13374 Class A.

Scope and requirements for use

Fallnet

®

 ASG may only be used for its intended purpose as an 

edge protection system for temporary maintenance work. Any 
changes or additions to the system components may not be 
carried out without the prior written permission of the manu-

facturer.

• The Fallnet

®

 ASG may be used up to a maximum roof     

   pitch of 5° in the direction of the falling edge.
• The edge protection system may be used during frosty 
   conditions provided the edge protection system was    
   installed in frost-free conditions.

Requirements relating to use and the users 
of Fallnet

®

 ASG

The Fallnet

®

 ASG collective edge protection system offers the 

advantage that it protects everyone working on a roof without 
them having to take special measures. 
The user is to be instructed to carry out the following visual 
and manual checks prior to starting work at the edge of a 
roof:

• visual check of the visible parts (e.g. for deformation, corrosion)
• visual check of the ballast depth

Evidence of restricted functioning could be, where:
• parts are deformed, weakened or very dirty and if they are 

 

  not in their original state,

• an uneven substrate height is established, e.g. due to drifting,
• the horizontal foot of the post module is visible.

If there is any doubt as regards the safe condition or proper 
functioning of the product, the client/the owner should be 
informed and the product must not be used until the matter is 

clarified.

Label

A label is attached to each post, handrail and mid rail and 
to the toe board with the following information: 

Manufacturer: 
ZinCo GmbH, Type Fallnet

®

 ASG

Standard: Collective edge protection system for temporary 
maintenance work as per EN 13374 Class A

Year and month of manufacture in that 
order. 

                              Authority used for certification

Details of the manufacturer and of the testing body

Manufacturer:

ZinCo GmbH

Lise-Meitner-Strasse 2
72622 Nürtingen, Germany
Tel. +49 7022 9060-770
Fax +49 7022 9060-610
info@zinco-greenroof.com
www.zinco-greenroof.com

Testing body:
DEKRA Testing and Certification GmbH

Dinnendahlstrasse 9

44809 Bochum, Germany

As of 2/2019, subject to technical changes,
we assume no liability for print errors, Art. no. 120011

Summary of Contents for Fallnet ASG

Page 1: ...Fallnet ASG Installation maintenance and user manual for the Fallnet ASG maintenance guardrail ...

Page 2: ... 6 Maintenance storage and Page 7 disposal User manual and Page 8 manufacturer s specifications Assembly 7 Install the green roof to provide static equilibrium 4 5 Lay the protection mat Install the post module 1 2 Loosen transport safety device Position the post at the required angle 3 Fix the position of the post Maintenance guardrail Fallnet ASG ...

Page 3: ...e mid rail is 0 3 m here The handrail or the mid rail can be extended by locking one element into another The connectors are to be inserted as far as possible The connectors for the handrails mid rails and corner connectors are secured with a drilling screw Corner joints are to be used for the corners of the handrail and mid rail The distance between the corner joint and the post is max 0 44 mm on...

Page 4: ...olt Step 2 Place the post at the required angle Draw up the post to 90 and insert the screw Draw up the post to 67 5 and insert the screw Step 3 Fixing the posts for a post at 90 angle for a post at 67 5 angle Fit washer and nut and tighten Fit washer and nut and tighten Step 4 Installing a protection mat on the roof Regardless of the required angle of the post on the guard rail a protection mat w...

Page 5: ... less than 15 cm Please ensure that the space between the lower edge of the toe board and the surface of the substrate is always less than 20 mm There are two types of mounting here depending on the height of the green roof build up Case 1 Using the upper slotted hole at the post foot for a post at 90 angle for a post at 67 5 angle Insert two hammer head bolts per post into the lower T groove of t...

Page 6: ...o zinco greenroof com www zinco greenroof com 6 Installation manual Layout example The height of the attica has to be at least 150 mm above the upper edge of the working area otherwise toe boards are to be installed max 0 44 m max 1 65 m max 0 44 m max 1 65 m Attention The roof pitch must not exceed 5 max 2 60 m ...

Page 7: ...condition is to be maintained In addition to checking the static equilibrium the guard rail system is to be checked once a year to ensure that it is complete and that the connections are tight and to check for possible corrosion Defective or missing components are to be replaced Loose connections are to be tightened Disposal Where they are no longer required the components of the ZinCo Fallnet ASG...

Page 8: ...ASG collective edge protection system offers the advantage that it protects everyone working on a roof without them having to take special measures The user is to be instructed to carry out the following visual and manual checks prior to starting work at the edge of a roof visual check of the visible parts e g for deformation corrosion visual check of the ballast depth Evidence of restricted funct...

Reviews: