How to connect Antenna Units (AU) to the Hub (HU)
CAUTION
Electrostatic discharge
(
ESD) preventative measures (i.e. wrist straps, use
of ESD protective bags) should be taken when storing, transporting and handling
SFPs as voltages in excess of 50V can cause damage to the device.
Hold the SFPs by the metal body and insert it into the designated HU and AU optical
slots. An audible click can be heard when the SFP is fully latched. Ensure that the
de-latch bail is in the upright position.
Figure 15
Removal of the SFP is achieved by extending the de-latch bail and pulling it away
from the unit.
Figure 16
Remove the protective end caps and connect the patch cord between the SFP on the
HU (Figure 11) and the local end of the Installed Fibre and between the remote end
of the Installed Fibre and the SFP on the AU. (Figure 12)The optical connectors are
keyed and care must be taken when inserting them.
Figure 17
Figure 18
NOTE
Using patch cords other than those specified by ZinWave can affect the
overall performance of the system.
Issue 3
Page 14 of 31
15/11/2006